CONNECTOR PIPE INSTAllATION
lOCATINg STOvE continued…
1.  The smooth end of the stovepipe fits over the cast 
iron flue collar at top rear of stove (fig. 5).
 
a).  Crimped  end  of  pipe  must  be  away  from 
stove.
 
b).  Hand form lower end (fig. 6) of stove pipe to 
oval shape (fig. 7) and slide over flue outlet collar 
as shown in figure 5.
 
c).  Secure  stove  pipe  to  flue  collar  with  
at least three (3) sheet metal screws and seal with 
stove cement.
2.  Horizontal  pipe  runs  must  slope  upwards  
towards the chimney at least 1/4” per foot of hori-
zontal run.
3.  You must have at least 18 inches of clearance be-
tween any horizontal piping and the ceiling.
4.  The pipe cannot extend into the chimney flue (figure 
8).
5.  Secure  pipe/elbow  sections  with  three  (3)  sheet 
metal  screws  at  each  joint  to  make  the  piping 
rigid.
6.  It is recommended that no more than two (2) 90 
degree bends be used in the stovepipe installation. 
The use of more than two 90 degree  bends may 
decrease the amount of draw and possibly cause 
smoke  spillage.  Where  possible,  use  only  cor-
rugated (nonadjustable) elbows. These provide a 
better seal.
7.  The connector pipe must not pass through an attic 
or roof space, closet, or any concealed space, or 
floor, ceiling, wall or combustible construction. A 
UL 103 HT Listed chimney must be used from the 
first penetration of ceiling or wall to the chimney 
cap. Never use single wall connector pipe as a 
chimney - a house fire could result. 
 
CorreCT 
WronG 
WronG
NOTE:  STOVE  PIPE  IS  NOT  INClUDED.   
TO  PURCHASE  PIPE, VISIT YOUR  LOCAL 
HARDwARE,  HOmE  OR  BUILDING  CEN-
TER.  SEE “LOCATING  STOVE”  PAGE  4  FOR   
ADDITIONAL SPECIFICATIONS.
CAUTION:  kEEP  FURNISHINGS  AND  OTHER   
COmBUSTIBLE mATERIALS AwAY FORm THE 
STOVE.
Fig. 5 –  Flue Outlet Collar
Fig. 6 –  Hand-form pipe to oval shape – Fig. 7
Fig. 8 – Stovepipe/Flue Connections