T8600D CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATS
69-1409—1
2
Wallplate Installation
The thermostat can be mounted horizontally on the wall 
or on a 2 in. x 4 in. (50.8 mm x 101.6 mm) wiring box. 
Position wallplate horizontally on the wall or on a 
2 in. x 4 in. (50.8 mm x 101.6 mm) wiring box.
1. Position and level the wallplate (for appearance 
only). The thermostat will function correctly even 
when not level. 
Fig. 1.  Typical location of thermostat.
Fig. 2. Mounting the wallplate.
2. Use a pencil to mark the mounting holes. See Fig. 
2.
3. Remove the wallplate from the wall and drill two 
3/16 inch (76 mm) holes in the wall (if drywall) as 
marked. For firmer material such as plaster, drill 
two 7/32 inch (5.56 mm)  holes. Gently tap anchors 
(provided) into the drilled holes until flush with the 
wall.
4. Position the wallplate over the holes, pulling wires 
through the wiring opening.
5. Loosely insert the mounting screws into the holes.
6. Tighten mounting screws.
WIRING
All wiring must comply with local electrical codes and 
ordinances. Refer to Fig. 3 through 5 for typical hookups. 
A letter code is located near each terminal for 
identification.
CAUTION
Electrical Hazard. 
Can cause electrical shock or equipment 
damage.
Disconnect power before wiring.
1. Loosen the terminal screws on the wallplate and 
connect the system wires. See Fig. 6.
IMPORTANT
Use 18 gauge, color-coded thermostat cable for 
proper wiring.
2. Securely tighten each terminal screw.
3. Push excess wire back into the hole.
4. Plug the hole with nonflammable insulation to    
prevent drafts from affecting the thermostat.
Fig. 3. Typical hookup in heat only application.
5 FEET
[1.5 METERS]
YES
NO
NO
NO
M10106
WIRES 
THROUGH WALL
WALL
MOUNTING 
HOLES
M15044
MOUNTING 
SCREWS
WALL
ANCHORS (2)
L1
(HOT)
L2
M10346A
FAN
RELAY
G
THERMOSTAT
HEAT
RELAY
R
RC
W
TRANSFORMER
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND 
OVERLOAD PROTECTION AS REQUIRED.
NOT AVAILABLE ON T8600A MODELS.
1
2
1
2