10
Programming 
 
 
Batch Settings 
Display 
 
™
 
Turn the brewer off by pressing the main power switch. 
 
 
 
™
 
Press the main power switch again to turn the unit on. 
         52 
 
The last 2 digits of the model number will display briefly, then S t b
  S t b 
 
 
™
 
Quickly hold the STOP button for 3 seconds. 
     P r G 
 
 
™
 
The display will show the software version.   Example: 
0.0  4.8 
 
 
™
 
Press STOP to continue. 
 
 
 
™
 
Batches are numbered 1 – 3 
(CBS-2051e)
 or 1 – 6 
(CBS-2052e / 2052e20)
 
 
 
                   
 
 
™
 
Next, the first batch parameter is displayed – batch 1, brew volume  
1.1  1.50 
 
       Use the SCROLL UP and SCROLL DOWN buttons to adjust. 
 
 
       Press the STOP button to go to the next parameter – brew time. 
1.2  4.00 
 
 
™
 
Continue this way until all parameters are programmed for batch #1. 
(See the chart below for an explanation of each parameter.) 
 
 
 
™
 
Next, batch #2 programming begins. 
2.0  OFF 
 
     Batches 2, 3, 5, and 6 may be disabled by leaving them set to “OFF”.
      Change to “ON” to enable.  Batches 1 and 4 cannot be disabled. 
 
 
 
™
 
After all batches are programmed, go to temperature settings. 
7      200 
 
(See next page) 
 
 
 
 
Important! After programming, you must press the HOT WATER button to save the settings and exit 
programming mode, or changes will be lost.  You may exit programming at any time. 
 
Batch Parameters 
      X=Batch Number (1 - 6) 
Parameter Name 
Range 
Increment Default 
Setting 
Comment 
X.0 
Batch Enabled or 
Disabled 
On/Off 
 
Batch 1 & 4 = ON 
Batch 2, 3, 5, 6 = OFF 
Batch 1 & 4 cannot 
be disabled. 
X.1 Brew 
Volume 
(Gallons)  
0.25 – 3.00 
0.01 
1.5 gal. (2051e/2052e) 
2.0 gal. (2052e20) 
To display liters, see 
# 59 in Advanced 
Settings section. 
X.2 
Brew Time (Min:Sec)  2:00 – 24:00 
0:30 
4:00 minutes 
 
X.3 
Bypass Percent 
0.00 – 40.0% 
1% 
0 % 
Percentage of total 
brew volume 
X.4 
Prewet Percent 
0.00 – 15.0% 
1% 
0 % 
Percentage of total 
brew volume 
X.5 Prewet 
Delay 
(Min:Sec) 
0:10 – 5:00 
0:10 
1:00 minute 
The time between 
prewetting and start 
of brew cycle. 
X.6 
Drip Delay (Min:Sec) 
0:30 – 6:00 
Minutes 
0:10 
1:30 minute 
The time between 
end of brew cycle 
and unlocking of 
brew basket. 
1.1  1.50 
PARAMETER 
SETTING 
BATCH # 
Example: 
    Left Side – Large Batch – Volume 1.5 Gal.