CHECKING GAS CONNECTIONS
 WARNING: Test all gas piping 
and  connections,  internal  and 
external to unit, for leaks after 
installing or servicing. Correct 
all leaks at once.
  WARNING:  Never  use  an 
open flame to check for a leak. 
Apply a noncorrosive leak detec-
tion fluid to all joints. Bubbles 
forming show a leak. Correct all 
leaks at once.
 CAUTION: Make sure exter-
nal regulator has been installed 
between  propane/LP  supply 
and heater. See guidelines un-
der Connecting to Gas Supply
page 14.
PRESSURE TESTING GAS SUPPLY 
PIPING SYSTEM 
Test Pressures In Excess Of 1/2 PSIG 
(3.5 kPa)
1.  Disconnect  appliance  with  its  appliance 
main gas valve (control valve) and equip-
ment shutoff valve from gas supply piping 
system. Pressures in excess of 1/2 psig 
will damage heater regulator.
2.  Cap off open end of gas pipe where equip-
ment shutoff valve was connected.
3.  Pressurize supply piping system by either 
opening  propane/LP  supply  tank  valve 
for propane/LP gas or opening main gas 
valve  located  on  or  near  gas  meter  for 
natural gas or using compressed air.
4.  Check all joints of gas supply piping system. 
Apply noncorrosive leak detection fluid to 
all joints. Bubbles forming show a leak.
5.  Correct all leaks at once.
6.  Reconnect heater and equipment shutoff 
valve to gas supply. Check reconnected 
fittings for leaks.
Test Pressures Equal To or Less Than  
1/2 PSIG (3.5 kPa)
1.  Close  equipment  shutoff  valve  (see 
Figure 17).
2.  Pressurize supply piping system by either 
opening  propane/LP  supply  tank  valve 
for propane/LP gas or opening main gas 
valve  located  on  or  near  gas  meter  for 
natural gas or using compressed air.
3.  Check all joints from gas meter to equipment 
shutoff valve for natural gas or propane/LP 
supply to equipment shutoff valve for pro-
pane/LP (see Figures 18 and 19, page 16). 
Apply noncorrosive leak detection fluid to 
all joints. Bubbles forming show a leak.
4.  Correct all leaks at once.
Figure 17 - Equipment Shutoff Valve
Open
Closed
Equipment 
Shutoff 
Valve
Figure 18 - Checking Gas Joints 
(Propane/LP Model Shown)
Gas Control 
Valve Location
Propane/LP 
Supply Tank
Equipment 
Shutoff Valve
Figure 19 - Checking Gas Joints (Natural 
Gas Only)
Gas Meter
Gas Control Valve 
Location
Equipment 
Shutoff Valve