Note: Home owners generally prefer to oper-
ate  their  heater  with  the  chimney  damper 
closed. This will put all the heat into the room. 
However, there may be times you will desire 
the full flames of the HI heat setting but will 
find the heat output excessive. You can open 
the chimney damper (if you have one) fully or 
partially to release some of the heat.
  WARNING:  Damper  handle 
will  be  hot  if  heater  has  been 
running.
1.  STOP!  Read  the  safety  information, 
page 18.
2.  Make  sure  equipment  shutoff  valve  is 
fully open.
3.  Press in and turn control knob clockwise 
 to the OFF position.
4.  Wait five (5) minutes to clear out any gas. 
Then smell for gas, including near the floor. 
If you smell gas, STOP! Follow “B” in the 
safety  information,  page  18.  If  you  don’t 
smell gas, go to the next step.
5.  Slightly  depress  and  turn  control  knob 
counterclockwise 
  to  the  PILOT 
position.  Keep  control  knob  pressed  in 
for five (5) seconds (see Figure 23).
 
Note:  You  may  be  running  this  heater 
for the first time after hooking up to gas 
supply. If so, the control knob may need 
to be pressed in for 30 seconds or more. 
This will allow air to bleed from the gas 
system.
6.  With control knob pressed in, press and 
release ignitor button. This will light pilot. 
The  pilot  is  attached  to  the  burner.  If 
needed, keep pressing ignitor button until 
pilot lights.
 
Note:  If  pilot  does  not  light,  contact  a 
qualified service person or gas supplier for 
repairs. Until repairs are made, light pilot 
with match. To light pilot with match, see 
Manual Lighting Procedure, page 20.
Figure 23 - Control Knob and Ignitor 
Button Location
Control Knob
Ignitor Button
OPERATION 
Continued
MANUALLY-CONTROLLED MODELS
7.  Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds, 
release control knob.
• If control knob does not pop out when 
released,  contact  a  qualified  service 
person or gas supplier for repairs.
 
Note:  If  pilot  goes  out,  repeat  steps  3 
through 7.
8.  Slightly  depress  and  turn  control  knob 
counterclockwise 
 to the HI position. 
The burner should light. Set control knob 
to any heat level between HI and LO.
9.  To leave pilot lit and shut off burners only, 
turn control knob clockwise 
 to the 
HI position then press in and turn clock-
wise 
 to PILOT position.
 CAUTION: Do not try to ad-
just heating levels by using the 
equipment shutoff valve.
VARIABLE CONTROL 
OPERATION
The variable control valve can be set to any 
heat setting and flame height desired, by sim-
ply turning the control knob until that setting 
is attained. Even the lowest setting provides 
realistic,  dancing  yellow  flames.  Selecting 
higher settings produces greater heat output. 
This results in increased heating comfort.
  WARNING:  Do  not  operate 
heater  between  PILOT  and  HI 
positions.
 CAUTION: Do not try to ad-
just heating levels by using the 
equipment shutoff valve.
TO TURN OFF GAS 
TO APPLIANCE
1.  Press in and turn control knob clockwise 
 to the HI position.
2.  Turn the control knob clockwise 
 to 
the PILOT position.
3.  Press in control knob and turn clockwise 
 to the OFF position.
4.  Close equipment shutoff valve (see Figure 
17, page 16).