6.0  power requirements
Jacuzzi spas are designed to provide optimum  
performance and flexibility of use when connected to the 
maximum electrical service listed below. Minor circuit 
board modifications can be performed to allow your new 
spa to accept an electrical service other than the factory 
operation setting. 
note: Refer to pages 46-47 for circuit board configuration details or 
contact your authorized Jacuzzi dealer.
north american models (60 Hz)
240V/40A*
240V/50A**
240V/60A***
Circuit Breaker (2-Pole):
40A
50A
60A
Number of Wires:
3
3
3
Frequency:
60 Hz
60 Hz
60 Hz
Current Draw:
26A
36A
45A
*  In 40A configuration, the heater will not operate while either jets 
pump is running in high speed. Note: pump 2 runs only in high 
speed.
**  In 50A configuration, the heater will not operate while both jets 
pumps are running in high speed. This is the factory setting. 
Note: pump 2 runs only in high speed.
***  In 60A configuration the heater will operate while both jets pumps 
are running in high speed.
export models (50 Hz)
230V/20A*
230V/30A**
230V/40A***
Circuit Breaker:
20A
30A
40A
Number of Wires:
3
3
3
Frequency:
50 Hz
50 Hz
50 Hz
Current Draw:
15A
23A
29A
*  In 20A configuration, the heater will not operate while either jets 
pump is running in high speed. This is the factory setting. Note: 
pump 2 runs only in high speed.
**  In 30A configuration, the heater will operate while one jets pump 
is running in high speed. Note: pump 2 runs only in high speed.
***  In 40A configuration the heater will operate while both jets pumps 
are running in high speed.