National Instruments 800 Series 用户手册

下载
页码 104
Appendix C
LED Indicators
© National Instruments Corporation
C-3
If either the SYSFAIL or FAILED LED remains lit, perform the 
following steps.
1.
Power off the mainframe.
2.
Remove all other modules from the mainframe.
3.
Make sure that the VXIpc 800 jumper settings are correct.
4.
Make sure that the VXIpc 800 is seated properly in the mainframe. 
5.
Power on the mainframe and observe whether the SYSFAIL and 
FAILED LEDs become unlit some time before the operating 
system boots.
Board Access LEDs
The board access LEDs—ACCESS and DRIVE—indicate when board 
resources have been accessed. The following paragraphs describe these 
LEDs.
ACCESS LED
When lit, the ACCESS LED indicates that the VXIpc 800 MODID line 
is asserted or that another VXIbus master is accessing VXIbus shared 
registers or shared memory.
DRIVE LED
The DRIVE LED light indicates that an access to the internal hard disk 
drive is occurring.
Ethernet LEDs
The Ethernet LEDs (RXTXLINK, and DSEL) indicate the status of 
the Ethernet interface on the VXIpc 800 Series.
RX LED
The RX LED lights when the Ethernet interface is receiving a packet.
TX LED
The TX LED lights when the Ethernet interface is transmitting a packet.