National Instruments 3.21E+04 用户手册

下载
页码 181
Chapter 3     Hardware Overview
AT-MIO/AI E Series User Manual
3-14
 National Instruments Corporation
Analog Output 
AT-MIO-16E-1, AT-MIO-16E-2, AT-MIO-64E-3, 
AT-MIO-16E-10, AT-MIO-16DE-10
The AT E Series boards supply two channels of analog output 
voltage at the I/O connector.   You can select the reference and 
range for the analog output circuitry through software.  The 
reference can be either internal or external, whereas the range can 
be either bipolar or unipolar.
AT-MIO-16XE-50
The AT-MIO-16XE-50 supplies two channels of analog output 
voltage at the I/O connector.  The range is fixed at bipolar 
±
10 V.
AT-MIO-16XE-10
The AT-MIO-16XE-10 supplies two channels of analog output 
voltage at the I/O connector.  The range is software selectable 
between unipolar (0 to 10 V) and bipolar (+10 V).
Analog Output Reference Selection
AT-MIO-16E-1, AT-MIO-16E-2, AT-MIO-64E-3, 
AT-MIO-16E-10, AT-MIO-16DE-10 only
You can connect each D/A converter (DAC) to the AT E Series  
board internal reference of 10 V or to the external reference signal 
connected to the external reference (EXTREF) pin on the I/O 
connector.  This signal applied to EXTREF should be between 
-10 and +10 V.  You do not need to configure both channels for the 
same mode.
Analog Output Polarity Selection
AT-MIO-16E-1, AT-MIO-16E-2, AT-MIO-64E-3, 
AT-MIO-16E-10, AT-MIO-16DE-10 only
You can configure each analog output channel for either unipolar 
or bipolar output.  A unipolar configuration has a range of 0 to V
ref
  
at the analog output.  A bipolar configuration has a range of -V
ref
 
to +V
ref
  at the analog output.  V
ref
  is the voltage reference used by 
the DACs in the analog output circuitry and can be either the 
+10 V onboard reference or an externally supplied reference 
between -10 and +10 V.  You do not need to configure both 