National Instruments 3.21E+04 用户手册

下载
页码 181
Chapter 4     Signal Connections
 National Instruments Corporation
4-7
AT-MIO/AI E Series User Manual
PFI2/CONVERT* 
DGND
Input
Output
PFI2/Convert—As an input, this is one of the PFIs.  
As an output, this is the CONVERT* signal.  A high-to-low 
edge on CONVERT* indicates that an A/D conversion is 
occurring.
PFI3/GPCTR1_SOURCE 
DGND
Input
Output
PFI3/Counter 1 Source—As an input, this is one of the 
PFIs.  
As an output, this is the GPCTR1_SOURCE signal.  This 
signal reflects the actual source connected to the 
general-purpose counter 1.
PFI4/GPCTR1_GATE
DGND
Input
Output
PFI4/Counter 1 Gate—As an input, this is one of the PFIs.  
As an output, this is the GPCTR1_GATE signal.  This signal 
reflects the actual gate signal connected to the 
general-purpose counter 1.
GPCTR1_OUT
DGND
Output
Counter 1 Output—This output is from the general-purpose 
counter 1 output.
PFI5/UPDATE*
DGND
Input
Output
PFI5/Update—As an input, this is one of the PFIs.  
As an output, this is the UPDATE* signal.  A high-to-low 
edge on UPDATE* indicates that the analog output primary 
group is being updated.
PFI6/WFTRIG
DGND
Input
Output
PFI6/Waveform Trigger—As an input, this is one of the 
PFIs.  
As an output, this is the WFTRIG signal.  In timed analog 
output sequences, a low-to-high transition indicates the 
initiation of the waveform generation.
PFI7/STARTSCAN
DGND
Input
Output
PFI7/Start of Scan—As an input, this is one of the PFIs.  
As an output, this is the STARTSCAN signal.  This pin 
pulses once at the start of each analog input scan in the 
interval scan.  A low-to-high transition indicates the start of 
the scan.
PFI8/GPCTR0_SOURCE
DGND
Input
Output
PFI8/Counter 0 Source—As an input, this is one of the 
PFIs.  
As an output, this is the GPCTR0_SOURCE signal.  This 
signal reflects the actual source connected to the 
general-purpose counter 0.
Signal Name
Reference
Direction
Description  
 
 (Continued)