FMI VEF21B 用户手册

下载
页码 16
www.fmiproducts.com
120926-26C
11
CLEANING AND MAINTENANCE
Continued
REPLACING  FLAME  GENERATION 
LED
1.  Follow steps 1 through 4 under Cleaning 
Firebox, page 8
2.  Remove screws from each side of log that 
secures log to base and remove log (see 
Figure 10, page 8).
3.  Remove screws from sides and back of 
bottom panel of firebox.
4.  Gently lay unit on its back.
5.  There are several wires attached to bot-
tom panel. Carefully remove panel.
6.  Disconnect  wires  from  motor  and  LED 
drum assembly.
7.  Remove  screws  from  bottom  panel  to 
remove assembly.
8.  If motor on assembly fails, loosen clamps 
(see  Figure  17).  Remove  screws  from 
motor. Hold universal joint while removing 
motor and discard.
9.  Install new motor. Slide motor shaft into 
universal joint and tighten clamps.
10. Hold  LED  drum  assembly  in  place  on 
bottom panel and replace screws.
11. Reattach wires to motor and LED drum. 
Note: LED drum wires are polarity sensi-
tive  and  must  be  connected  correctly. 
White wire plugs onto left terminal and red 
wire plugs onto right terminal. Motor wires 
can be connected to either terminal.
LED Drum 
Assembly
Screws
White Wire
Red 
Wire
Figure 17 - Flame Generation LED Drum 
Assembly
Motor
12. Replace fireplace bottom panel. Set fire-
place upright and replace screws.
13. Replace log, glass and bracket.
14. Reinstall fireplace and replace trim.
CLEANING OR REPLACING BACK 
SCREEN (GLASS)
1.  The glass is cleaned in the factory during 
assembly.  During  shipment,  installation, 
handling, etc. glass surface may collect 
dust  particles.  These  can  be  removed 
by buffing lightly with a clean damp cloth 
(water only). Glass should be completely 
dried with a lint free cloth or paper towel.
2.  In the event of glass breakage, vacuum all 
remaining glass pieces with a shop vac. DO 
NOT VACUUM WHILE PIECES ARE HOT. 
Replace glass only with replacement part 
specifically for this heater. Never substitute 
material.  Only  fully  tempered  soda  lime 
safety glass may be used on this heater. 
3.  To  access  glass  to  clean  or  replace, 
follow  steps  1  and  7  under  Replacing 
Flame Generation LED. Set aside bottom 
panel.
4.  Remove screws securing log base to unit. 
Carefully remove log base from unit.
5.  Using gloves, gently remove glass panel 
by sliding it toward you. There is a rubber 
bumper on each corner of glass.
6.  Clean  glass  as  instructed  in  step  1  or 
replace glass.
7.  Using  gloves,  reinstall  glass  by  gently 
sliding, smooth side toward fireplace front, 
into brackets on either side that hold glass 
in place.
8.  Replace log base.
9.  Follow steps 11 and 14 under Replacing 
Flame Generation LED.
TEChNICAL SERVICE
You may have further questions about instal-
lation,  operation  or  troubleshooting.  If  so, 
contact FMI PRODUCTS, LLC at 1-866-328-
4537. When calling please have your model 
and serial numbers of your heater ready. This 
information  is  located  on  the  inside  of  the 
control panel door (Figure 2, page 4).
You can also visit our web site at 
www.fmiproducts.com.
Clamps