Chapter 3    Configuring and Testing
© National Instruments Corporation
3-3
NI-DAQmx
In NI-DAQmx, you can configure software settings such as filter 
bandwidth and gain/input signal range in the following ways:
Task or global channel in MAX
Functions in your application
Note 
All software-configurable settings are not configurable both ways. This section only 
discusses settings in MAX. Refer to Chapter 4, 
, for information on 
using functions in your application.
These sections describe settings that you can change in MAX and where 
they are located.
Filter bandwidth—configure the Device tab using either NI-DAQmx 
Task
 or NI-DAQmx Global Channel. You also can set the value 
through your application.
Input signal range—configure the input signal range using either 
NI-DAQmx Task or NI-DAQmx Global Channel. When you set the 
minimum and maximum range of NI-DAQmx Task or NI-DAQmx 
Global Channel
, the driver selects the best gain for the measurement. 
You also can set it through your application.
Modes of operation—configure only using chassis installation in 
software. Refer to Chapter 1, 
, for more 
information on chassis installation. The default setting in NI-DAQmx 
is multiplexed.
Terminal block attenuation—for terminal blocks with manually 
adjustable attenuation such as the SCXI-1327, you must configure the 
attenuator in the chassis configurator. Refer to the SCXI Quick Start 
Guide
 for more information.
Note 
Refer to Chapter 4, 
, for information on configuring the settings 
for your application using Traditional NI-DAQ (Legacy).
Creating a Voltage Global Channel or Task
To create a new NI-DAQmx global task or channel, complete the following 
steps:
1.
Double-click Measurement & Automation on the desktop.
2.
Right-click Data Neighborhood and select Create New.
3.
Select NI-DAQmx Task or NI-DAQmx Global Channel, and click 
Next.