National Instruments NI PXI-6542 用户手册

下载
页码 32
NI Digital Waveform Generator/Analyzer Guide
20
ni.com
Table 4.  NI 654X DDC Connector Pins
Pins
Signal 
Name
Signal 
Type
Signal Description
33
DDC CLK
OUT
Control
Output terminal for the exported 
Sample clock.
67
STROBE
Control
Terminal for the external Sample clock 
source which can be used for pattern 
acquisition.
1, 3, 5, 7, 9, 
11, 13, 15, 17, 
19, 21, 23, 25, 
27, 29, 31, 35, 
37, 39, 41, 43, 
45, 47, 49, 51, 
53, 55, 57, 59, 
61, 63, 65
DIO <0..31>
Data
Bidirectional digital I/O data channels 
0 through 31.
26, 30, 64
PFI <1..3>
Control
Input terminals to the NI 654X for 
external triggers, or output terminals 
from the NI 654X for events.
2, 4, 6, 10, 12, 
14, 16, 18, 20, 
22, 24, 28, 32, 
34, 36, 38, 40, 
42, 44, 46, 48, 
50, 54, 56, 58, 
62, 66
GND
Ground
Ground reference for signals.
8, 52, 60
RESERVED
N/A
These terminals are reserved for future 
use. Do not connect to these pins.