TROUBLESHOOTING
Continued 
POSSIBLE CAUSE
1. Not enough combustion/
ventilation air
1. Turning control knob to HI 
or position 5 when burner is 
cold
2. Air in gas line
3. Air passageways on heater 
blocked
4. Dirty or partially clogged 
burner orifice
1. When heated, vapors from 
furniture polish, wax, carpet 
cleaners, etc. may turn into 
white powder residue
1. Metal  expanding  while 
heating or contracting while 
cooling
REMEDY
1. Refer to Air for Combustion 
and Ventilation require-
ments (page 6)
1. Turn control knob to LO or 
position 1 and let warm up 
for a minute
2. Operate burner until air is 
removed from line. Have 
gas line checked by local 
propane/LP or natural gas 
company
3. Observe minimum installation 
clearances (see page 9)
4. Clean burner (see Cleaning 
and Maintenance, page 03) 
or replace burner orifice
1. Turn  heater  off  when  us-
ing  furniture  polish,  wax, 
carpet cleaners or similar 
products
1. This  is  normal  with  most 
heaters. If noise is exces-
sive, contact qualified ser-
vice person
OBSERVED PROBLEM
Moisture/condensation no-
ticed on windows
Heater produces a whistling 
noise when burner is lit
White powder residue form-
ing within burner box or on 
adjacent walls or furniture
Heater produces a clicking/
ticking noise just after burner 
is lit or shut off