FCC PART 15 RADIO FREQUENCY DEVICES
This equipment has been tested and found to comply with the limits for a Class B digital device
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications, However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-- Consult the dealer or an experienced radio/TV technician for help.
CAUTION (AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL)
"Early warning fire detection is best achieved by the installation of fire detection equipment in all
rooms and areas of the household as follows. A smoke alarm installed in each separate sleeping
area (in the vicinity of, but outside of the bedrooms), and heat or smoke detectors in the living
rooms, dining rooms, bedrooms, kitchens, hallways, attics, furnace rooms, closets, utility and storage
rooms, basements and attached garages.
Page 8
THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY,
UL217 BY UNDERWRITERS LABORATORIES, INC.
Blinks On once
approx every
40-45 seconds
DC Power is present.
3 Beeps,
2 second pause,
Repeat
Blinks On approx
every 2 seconds
3 Beeps,
2 second pause,
Repeat
Blinks On approx
every 2 seconds
Blinks On once
approx every
40-45 seconds
(normal operation
mode) or Blinks on
once approx every
10 seconds
(silence mode)
Originating smoke alarm - If hazard is identified, please take
all precautions if an alarm sounds by calling an Emergency
Service and getting out of the home.
OPERATIONAL SUMMARY
Silent
Blinks On once
approx every
40-45 seconds
Silent
1 Chirp
approx every
40 seconds
Low Battery - Check to make sure the battery activation pull-
tab has been completely removed, battery polarity is correct
and the battery terminals are making contact with the smoke
alarm contacts in the battery drawer. If chirp continues, replace
the 9V battery (see User's Manual for recommended battery
types).
To Reset the Alarm - Hold the Test/Silence button for 10
seconds, or temporarily remove (and then replace) the battery.
This will clear alarm origination and clear Silence mode. Reset
after each smoke alarm 
event.
Nuisance Alarm - If there is no hazard present, verify the
alarm is mounted in the correct location (see User's Manual,
"AVOID THESE LOCATIONS" section). Reset alarm as
instructed below.
3 Beeps,
2 second pause,
Repeat
Silence Feature is activated by pressing and releasing the
Test/Silence button on the initiating alarm while in alarm
condition. Silence mode will last for 8-12 minutes.
Blinks On approx
every 2 seconds
Silent
(alarmed
previously)
Blinks On once
approx every
40-45 seconds (normal
operation mode) or
Blinks On once approx
every 10 seconds
(silence mode)
CONDITION OF ALARM AUDIBLE & VISUAL SIGNALS BEFORE SOLUTION / RECOMMENDATION
SOLUTION / RECOMMENDATION
HORN
RED LED
QUICK FIND
®
 ALARM ORIGINATION: The QUICK FIND
®
feature will allow you to immediately locate the originating
alarm (once the alarm has stopped sounding). To initiate
QUICK FIND
®
, press the Test/Silence button on each alarm.
After releasing the button, the originating alarm will continue
to sound for 60 seconds. In a non-interconnected installation,
it is necessary to test each alarm to determine the originating
alarm. Reset the orginating alarm.