brocade-communications-sy rfs6000 用户手册

下载
页码 839
776
Brocade Mobility RFS4000, RFS6000 and RFS7000 CLI Reference Guide 
53-1001931-01
smart-rf config commands
25
hold-time
Defines the number of seconds to disable interference avoidance after a detection 
This prevents a radio from changing channels continuously.
Supported in the following platforms:
Mobility RFS4000 Controller
Mobility RFS6000 Controller
Mobility RFS7000 Controller
Syntax
hold-time 
<30-65535>
Parameters
Example
RFController(config-wireless-smart-rf)#hold-time 400
RFController(config-wireless-smart-rf)#
hold-time <30-65535>
The number of seconds to disable interface avoidance after a 
detection. This prevents the radio from changing channels 
continuously. Set the values in seconds from 30-65535.