Datalogic Scanning powerscan d8330 用户手册

下载
页码 212
POWERSCAN
®
 D8330/M8300 
142 
 
 
5.1.4 
RX Timeout 
 
When the RS-232 interface is selected, the Host can be used to configure the device 
by sending it command strings (see Appendix A). 
 
This parameter can be used to automatically end data reception from the Host after 
the specified period of time. 
 
If no character is received from the Host, after the timeout expires, any incomplete 
string (any string not terminated by <CR>) is flushed from the device buffer. 
 
 
5.2  PEN PARAMETERS 
 
5.2.1 
Minimum Output Pulse 
 
This parameter sets the duration of the output pulse corresponding to the narrowest 
element in the barcode. In this way the code resolution is controlled by the signal 
sent to the decoder, independently of the physical resolution of the code read. 
 
The shortest pulse (200 
μs) corresponds to a high-resolution code emulation and 
therefore a shorter transfer speed to the decoder (for decoders able to work on high 
resolution codes). Likewise, longer pulses correspond to low-resolution code 
emulation and therefore a longer transfer time to the decoder. 
 
 
5.2.2 
Conversion to Code 39 and Code 128 
 
PowerScan
®
 D8330 Series Readers 
When using these readers it is possible to convert all codes to Code 39. By disabling 
this option the decoded codes will be transmitted in their original format, except for 
the following codes, which are ALWAYS converted into Code 39 format: 
MSI, Code 11, Code 16K, Code 49, GS1 DataBar™. 
 
 
PowerScan
®
 M8300 Series Readers 
When using these readers it is possible to choose between converting the decoded 
codes into either Code 39 format or Code 128 format. It is not possible to disable 
conversion.