INSTEON 2633-442 (uk) 用户手册

下载
页码 14
 
Page 11 of 14                                                                                                             Rev: 1/21/2014 7:47 AM
 
 
Electrical 
Voltage 
100VAC to 240VAC (+/- 10%) 
Frequency 
50/60Hz auto detected at power-up 
Maximum load 
16A – 240VAC (EUR) 
10A – 240VAC (AUS/NZ) 
3600W/240VAC Resistive 
700W/240VAC Inductive/Capacitive 
2000W/240VAC Bulbs/Low Voltage Halogen 
Minimum load 
N/A 
Load type(s) 
Resistive 
Inductive/capacitive 
Low voltage halogen 
Hardwired remote control 
N/A 
Retains all settings without power 
Yes, saved in non-volatile EEPROM 
Standby power consumption 
< 0.75 watts 
Safety approved 
CE, C-Tick 
Certifications 
EN 300 220-2, 301 489-3 
AS/NZS 4268, CISPR 22 
IEC 60669-2-1 
All product specifications are subject to change. 
Troubleshooting 
Problem 
Possible Cause 
Solution 
On/Off Module LED is not turning 
on 
On/Off Module is not 
getting power  
Make sure On/Off Module is not 
plugged into a switched outlet that is 
turned off 
On/Off Module won’t add to a 
scene as a controller or responder  
On/Off Module or the 
controller is plugged into a 
power strip or AC line filter 
Powerline signals can’t travel through 
some power filters. Plug On/Off 
Module or controller into an 
unswitched wall outlet. 
The INSTEON signal may 
be too weak 
Add additional INSTEON devices or 
move around existing INSTEON 
devices. All INSTEON devices act as 
INSTEON network repeaters.  
Large appliances, such as 
refrigerators or air 
conditioners, may be 
producing electrical noise 
on the powerline.