CHAPTER 6  STAND-ALONE FUNCTION
The stand-alone function erases, programs, or verifies data with the PG-FP3 alone, without the use of a host.  This
function is used on a production line when the application system is mass-produced, or used to upgrade a customer’s
version.
6.1  FUNCTION
The commands that can be executed in stand-alone mode are as follows:
Program command
Erase command
Verify command
E.P.V. command
PROM Load command
These commands are selected with the PG-FP3 MODE KEY.  The command currently selected can be identified by
an LED on the PG-FP3.  Execute the selected command by pressing the ENTER key.  The command is set in the
command mode specified by [E.P.V.] when the PG-FP3 is started.  The command mode changes as follows each time
the MODE key has been pressed:
  E.P.V. 
 Erase 
 Program 
 Verify 
 PROM Load 
 E.P.V. 
… 
While a command is being executed, the LED corresponding to the command blinks.
Caution
Loading the parameter file and setting the TYPE in stand-alone mode must be performed in
advance by the host via FLASHPRO3.  The information set using FLASHPRO3 is used as the
target setting information recorded in the PG-FP3 in stand-alone mode.