IBM PG-FP3 用户手册

下载
页码 95
User's Manual  U13502EJ2V0UM00
87
CHAPTER 8  ERROR MESSAGES AND REMEDIAL ACTIONS
Error No.
Message
Cause/action
Cause
Input of wrong command
ER01
Illegal command.
Action
Enter the correct command.
Cause
Input of wrong parameter during command input
ER02
Illegal parameter.
Action
Enter the correct parameter.
Cause
Incorrect interfacing with host machine
ER03
Host is closed.
Action
Check the connection between the PG-FP3 and the host.
Cause
An attempt was made to read flash memory.
ER04
Flash memory cannot read.
Action
Flash memory cannot be read.
Cause
PG-FP3 system error
ER05
SYSTEM error.
Action
The PG-FP3 may be damaged.
Cause
Intel HEX format cannot be recognized.
ER06
Intel HEX format error.
Action
Check to see if the file is in Intel HEX format, and reload the file.
Cause
A checksum error was detected during loading.
ER07
Check sum error
Action
Load the file again.
Cause
Initialization with the target microcontroller cannot be made.
ER08
Target initialize error.
Action
Check to see if the target device was correctly set with the TYPE
command.
Cause
The set target microcontroller has no signature.
ER09
Target no SIGNATURE.
Action
Check to see if the target device was correctly set with TYPE
setting.
Cause
The set target microcontroller has no EEPROM.
ER0A
No EEPROM.
Action
Check to see if the target device was correctly set with TYPE
setting (cannot be read).
Cause
The target microcontroller is not normal.
ER0B
Target return error.
Action
Communication with the target device is not normal.
Check to see if the correct communication rate was set with the
TYPE command.
Cause
An error was detected during communication with the target device.
ER0C
Target status no return.
Action
Check the connection with the target device again.
Cause
Execution has been forcibly terminated with the Start/Stop switch.
ER0D
SW STOP!!
Action
Redo the processing from the beginning.
Cause
An illegal character was detected in the displayed character string.
ER0E
No character.
Action
Turn off power to the PG-FP3 and then back on again.
Cause
The set target device is not divided into blocks.
ER0F
This DEVICE is NO BLOCK
Action
Block manipulation commands cannot be used if a microcontroller
that is not divided into blocks was selected with the TYPE
command.
Cause
The size of the EEPROM exceeds 64 Kbytes.
ER10
EEPROM size over flow.
Action
Check the Start/End address in the TYPE setting.