Linear DXS-80 用户手册

下载
页码 2
DXS-80
The DXS-80 is a UL listed
, single 
station, carbon monoxide alarm with 
a built-in supervised transmitter. It is 
compatible  with Linear’s wireless 
DXS Format Security Systems, Personal 
Emergency Reporting Systems (PERS), 
and other stand-alone receivers. The 
DXS-80 provides a warning to alert 
against both the acute and chronic 
effects of carbon monoxide (CO) 
poisoning.
When carbon monoxide is detected, 
the alarm sounds a loud local alarm. 
The built-in transmitter sends a digitally 
coded wireless signal to its companion 
receiver every 20 seconds until the air 
has cleared and the detector is restored.
The local alarm can be silenced once by pressing the test/
reset button. The transmitter will continue to send an alarm 
signal every 20 seconds. After 7 minutes, the alarm will sound 
again if there is still an unsafe carbon monoxide concentration 
level. The reset function can be used only once for each alarm 
occurrence.
No field coding is required because the DXS-80 is factory set to 
a unique code; one of over a million possible codes.
The DXS-80 is powered by one 3-volt 
lithium battery. The battery is supplied 
and can power the unit for up to the 
six year life of the detector. If the 
battery voltage drops below a preset 
level the alarm will sound a low 
battery chirp every 45 seconds and a 
low battery signal will be sent to the 
receiver.
At about 6 years, the carbon monoxide 
detector element will reach the end of 
its serviceable life. The self-supervising 
detector will signal a permanent 
trouble condition, indicating time for 
replacement.
SPECIFICATIONS
 REGULATORY 
LISTINGS: 
UL2034
 DETECTION 
METHODS: 
Electrochemical
TIME TO ALARM PER UL 2034:
Carbon Monoxide 
Concentration Level
Minimum Time 
to Alarm
Maximum Time 
to Alarm
50 ppm +/-5 ppm
30 days
Indefinite
70 ppm +/-5 ppm
60 min
240 min
150 ppm +/-5 ppm
10 min
50 min
400 ppm +/-5 ppm
4 min
15 min
 AUDIBLE 
OUTPUT: 85 
dBA/10'
  OPERATING TEMP. RANGE: 32º-100º 
F
 
POWER:  3-Volt battery (Lithium Type 123A)
 
 
(UL tested for greater than 1 year service life)
 
CURRENT:  7 mA alarm average, 15 µA standby
 
FREQUENCY: 315 
MHz
 
NUMBER OF CODES:  One of 1,048,576 possible codes
 
DIMENSIONS:  5.3" diameter, 2.0"h
 COMPATIBLE RECEIVERS
: PERS-3600 
PERS-2400A
  
DXSR-1504 
DXSR-1508
  
DVS-1200 
DXR-702
  
DUAL-824 
DVS-2400
Model DXS-80
(SST00116)
Carbon Monoxide Alarm
Wireless Carbon Monoxide 
Alarm
,
,
A
Model DXR-702
(SNR00149)
2-Channel Receiver
Also available as a kit:
DX-COKIT
(SSA00020)
Kit contains one DXR-702 receiver 
with a DXS-80 already learned into 
the receiver
NOTE: The DX-COKIT is not for use
in UL Listed applications
† The DXS-80 is currently UL Listed for use with the Linear PERS Consoles only. It has not 
been tested by UL with other compatible Linear receivers.