Lennox merit lmbv-36ren 用户手册

下载
页码 16
3
LENNOX MERIT
®
 SERIES B-VENT GAS FIREPLACES   •   36" LMBV MODELS   •   INSTALLATION INSTRUCTIONS
Carbon  monoxide  poisoning:  early  signs  of 
carbon monoxide poisoning are similar to the 
flu with headaches, dizziness and/or nausea. If 
you have these signs, obtain fresh air immedi-
ately. Turn off the gas supply to the appliance 
and have it serviced by a qualified professional, 
as it may not be operating correctly.
GeNeRAL INFORmATION
Note:  Installation  and  repair  should  be  per-
formed  by  a  qualified  service  person.  The 
appliance should be inspected annually by a 
qualified professional service technician. More 
frequent  inspections  and  cleanings  may  be 
required due to excessive lint from carpeting, 
bedding material, etc. It is imperative that the 
control compartment, burners and circulating 
air passage ways of the appliance be kept clean.
S'assurer que le brùleur et le compartiment 
des  commandes  sont  propres.    Voir  les 
instructions d'installation et d'utilisation qui 
accompagnent l'apareil.
These appliances are equipped with an integral 
combustion air door and actuator arm.  Combus-
tion air kits are optional and must be installed 
before removing the securing screw allowing 
the movement of the combustion air actuator 
arm (see Step 7).
WARNING:  THeSe  FIRepLACeS  ARe 
veNTed deCORATIve GAS AppLIANCeS. 
dO NOT bURN WOOd OR OTHeR mATe-
RIAL IN THeSe AppLIANCeS.
WARNING:  FAILURe TO COmpLY WITH 
THe  INSTALLATION  ANd  OpeRATING 
INSTRUCTIONS  pROvIded  IN  THIS 
dOCUmeNT  WILL  ReSULT  IN  AN  Im-
pROpeRLY INSTALLed ANd OpeRATING 
AppLIANCe, vOIdING ITS WARRANTY.  
ANY CHANGe TO THIS AppLIANCe ANd/
OR ITS OpeRATING CONTROLS IS dAN-
GeROUS.  ImpROpeR INSTALLATION OR 
USe OF THIS AppLIANCe CAN CAUSe 
SeRIOUS  INjURY  OR  deATH  FORm 
FIRe, bURNS, expLOSION OR CARbON 
mONOxIde pOISONING.
AveRTISSemeNT:  SURveILLeR  LeS 
eNFANTS.  GARdeR LeS vêTemeNTS, 
LeS meUbLeS, L'eSSeNCe OU AUTReS 
LIQUIdeS à vApeUR INFLAmmAbLeS 
LOIN de L'AppAReIL.
WARNING:  THIS AppLIANCe mAY ONLY 
be  FITTed  WITH  dOORS  CeRTIFIed 
FOR USe WITH THe AppLIANCe.  NO 
SUbSTITUTeS ALLOWed.
WARNING:  CHILdReN  ANd  AdULTS 
SHOULd be ALeRTed TO THe HAzARdS 
OF  HIGH  SURFACe  TempeRATUReS. 
USe  CAUTION  AROUNd  THe  AppLI-
ANCe TO AvOId bURNS OR CLOTHING 
IGNITION. YOUNG CHILdReN SHOULd 
be  CAReFULLY  SUpeRvISed  WHeN 
THeY ARe IN THe SAme ROOm AS THe 
AppLIANCe.
WARNING:  dO NOT pLACe CLOTHING 
OR  OTHeR  FLAmmAbLe  mATeRIALS 
ON OR NeAR THIS AppLIANCe.
WARNING:  eLeCTRONIC  mOdeLS  OF 
THeSe  AppLIANCeS  ARe  eQUIpped 
WITH  A  THRee-pRONG  (GROUNdING) 
pLUG  UTILIzed  IN  CONNeCTING  THe 
eLeCTRONIC  COmpONeNTS  TO  THe 
jUNCTION  bOx  IN  THe  LOWeR  COm-
pARTmeNT.    THIS  GROUNdING  pLUG 
pROvIdeS  pROTeCTION  AGAINST 
SHOCK  HAzARd  ANd  SHOULd  be 
pLUGGed  dIReCTLY  INTO  THe  pROp-
eRLY GROUNded THRee-pRONG ReCep-
TACLe.  dO NOT CUT OR RemOve THe 
GROUNdING pRONG FROm THe pLUG.
Do  not  use  these  appliances  if  any  part  has 
been under water. Immediately call a qualified, 
professional service technician to inspect the 
appliance and to replace any parts of the control 
system and any gas control which have been 
under water.
Ne  pas  se  servir  de  cet  appareil  s'il  a  été 
plongé  dans  l'eau,  complètement  ou  en 
partie.  Appeler un technicien qualifié pour 
inspecter l'appareil et remplacer toute partie 
du système de contrôle et toute commande 
qui ont été plongés dans l'leau.
This appliance may be installed in an after-
market permanently located, manufactured  
home (USA only) or mobile home, where not 
prohibited by local codes. This appliance is 
only for use with the type of gas indicated 
on  the  rating  plate.  This  appliance  is  not 
convertible for use with other gases, unless 
a certified kit is used.
Cet  appareil  peut  être  installé  dans  un 
maison  préfabriquée  (É.-U.  seulement) 
ou mobile  déjà  installée à demeure si 
les réglements locaux le permettent. Cet 
appareil doit être utilisé uniquement avec 
les types de gaz indiqués sur la plaque sig-
nalétique.  Ne pas l'utiliser avec d'autres 
gaz  sauf  si  un  kit  de  conversion  certifié 
est installé.
NeW YORK CITY, NeW YORK (meA)
Installation of these fireplaces are approved for 
installation in New York City in the US state of 
New York, if the following additional require-
ment is met:
•  An  outside  air  kit  (FOAK-4  or  FOAK-4LD) 
must be installed. See Installation Acces-
sories on page 13.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for 
service and proper operation. Never obstruct 
the front openings of the appliance.
massachusetts and New York 
Requirements
ReQUIRemeNTS FOR THe  
COmmONWeALTH OF mASSACHUSeTTS
These fireplaces are approved for installation in 
the US state of Massachusetts if the following 
additional requirements are met:
•  Install  this  appliance  in  accordance  with 
Massachusetts Rules and Regulations 248 
C.M.R.
•  Installation  and  repair  must  be  done  by  a 
plumber or gas fitter licensed in the Com-
monwealth of Massachusetts.
•  The flexible gas line connector used shall not 
exceed 36 inches (92 centimeters) in length.
•  The  individual  manual  shut-off  must  be  a 
T-handle type valve.