Chapter 3
VXI-MXI-2 Configuration and Installation
© National Instruments Corporation
3-13
Figure 3-8.  SMB Trigger Input Termination
MXIbus Termination
The first and last MXIbus devices connected to the MXIbus—whether it is 
a single MXI-2 cable or daisy-chained MXI-2 cables—must terminate the 
MXIbus. Any MXIbus devices in the middle of a MXIbus daisy chain must 
not terminate the MXIbus.
The VXI-MXI-2 automatically senses whether it is at either end of the 
MXIbus cable to terminate the MXIbus. You can manually control MXIbus 
termination by defeating the automatic circuitry. Use switches 1 and 2 
of the four-position switch at location U35 to control whether MXIbus 
termination is automatic (Figure 3-9a), on (Figure 3-9b), or off 
(Figure 3-9c). The settings of switches 3 and 4 have no effect on MXIbus 
termination.
a.  Non-Terminated External Trigger Input SMB (Default)
b.  Terminated External Trigger Input SMB with 50    
S2 Off
On
50    Termination for External Trigger Input
S3 Out
In
S4 Off
On
NON-INVERTED
INVERTED
S5
SMB CLK10 Direction
50    Termination for SMB CLK10 (Effective only when S3 is set to “IN”)
SMB CLK10 Output Polarity (Effective only when S3 is set to “OUT”)
S2 Off
On
50    Termination for External Trigger Input
S3 Out
In
S4 Off
On
NON-INVERTED
INVERTED
S5
SMB CLK10 Direction
50    Termination for SMB CLK10 (Effective only when S3 is set to “IN” )
SMB CLK10 Output Polarity (Effective only when S3 is set to “OUT”)