standard fluid level gauges. If, however, the tank has an irregular 
shape or greater accuracy is needed, calibration is recommended.  
The default calibration for the EP-10 Fuel Flow and Suzuki Engine 
Interface are adequate in most cases, but if Fuel Used readings are off 
by more than 3 percent, calibration is recommended. 
Calibrating EP-10 Fuel Flow 
The default calibration for an EP-10 Fuel Flow is adequate in most 
cases, but if fuel used readings are off by more than 3 percent, 
calibration is recommended.  
Fuel Flow Accuracy 
To check fuel flow accuracy, add the Fuel Manager page or any of the 
digital gauge pages to the page screen rotation, then customize the 
selected page with Fuel Used data. To see instructions on how to Add 
Pages and Customize Pages, refer to the Operation Section.  
NOTE: 
Make sure the fuel flow has been set as the Fuel Remaining Source, 
otherwise, you will not be able to calibrate the fuel flow. See Fuel 
Remaining Source instructions on page 28.  
After filling up your tank, take your vessel out on the water and burn 
at least five gallons of fuel. Be sure you run only ONE engine — 
the engine attached to your fuel flow.
  
Fill up your tank again, noting how much fuel you added to the tank. 
Compare that number to the Fuel Used figure displayed on the page 
you customized. If the amount of fuel you added to the tank and the 
fuel used figure are off by more than 3 percent, we recommend the fuel 
flow be calibrated. 
NOTE
You must use the gauge's Refill Tank command when filling your 
fuel tank to keep the fuel flow updated with correct information on 
the amount of fuel in the tank. 
Refill Tank 
You must use the Refill Tank command every time you fill up and 
every time you calibrate a fuel flow to make sure the fuel flow reads the 
tank as full. For more information on the Refill Tank function see page 
26. 
To calibrate an EP-10 Fuel Flow: 
Add the Fuel Manager page or any of the digital gauge pages to the 
page screen rotation then customize the selected page with Fuel Used 
data. To see instructions on how to Add Pages and Customize Pages, 
refer to the Operation Section.