Matrox DX002DWLS9OR Fiber Optic Cable 规格指南

下载
页码 3
Optical Cable Corporation reserves the right to change this specification without prior notification.
Distribution series Fiber optic cable
type oFnr riser proDuct speciFications
i/o 1 
  |  inDoor/outDoor cables
Applications
•  Indoor/outdoor tight-bound tight-buffered design allows cables to be installed
 in intra-building backbone and inter-building campus locations without costly
 transitions between cable types
•   Ideal configuration for a single termination point requiring multiple fibers
Features
•  High performance components
  and construction
•  Cable materials are indoor/outdoor –
 UL-listed OFNR and UV,
 water and fungus resistant
•  UL Listed in accordance
 with NEC section 770.179(b)
 for use in vertical runs in building  
 riser shafts or from floor to floor
•  Wide operating temperature range
 of -40°C to +85°C
•  Helically stranded core for greater flexibility
 and mechanical protection of the optical fibers
•  High strength-to-weight ratio
•  2-144 fiber configuration is smaller and lighter
 than comparable sub-grouped cables, which is
 ideal for installation in areas with limited
 space or tight bends
•  Can be armored for additional protection in direct burial and aerial installations
•  Interlocking armor can be applied to cables as an alternative to conduit installation
Cost savings
•  900 µm buffer eliminates the need for costly and time-consuming installation of
 fanout kits or pigtail splices because connectors terminate directly to the fiber.  
 See page PI-4 for typical termination approach.
•  No need to splice outdoor cable to indoor cable at building entrance
•  High crush resistance may eliminate the need for innerduct
D-Series Riser
Mechanical and Environmental Performance
indoor/outdoor
Operating Temperature
-40°C to +85°C
Storage Temperature
-55°C to +85°C
Installation Temperature (cable temp.)
-10°C to +60°C
Flame Retardancy
UL Listed Type OFNR (UL 1666)  
and FT4 (CSA C22.2 No. 232)
Impact Resistance:
1,500 impacts
Crush Resistance:
1,800 N/cm
Flex Resistance:
2,000 Cycles