Cisco 7000 SERIES PA 8 PORT T1 MC ADAPTER WITH CSU DSU 规格指南
4-38
Multichannel DS1/PRI Port Adapter Installation and Configuration
OL-3525-03
Chapter 4 Configuring the Multichannel DS1/PRI Interfaces
Checking the Configuration
DSX1 BERT k bits (last): 6165
Applique type is Channelized T1
Receiver has no alarms.
Cablelength is long gain36 0db
Framing is ESF, Line Code is B8ZS, Clock Source is Line.
Data in current interval (0 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
Router#
Cisco 7401ASR Routers
Router# show controllers t1 1/0
T1 1/0 is up. (Diagnostic Loopback)
DSX1 BERT pattern : zeros
DSX1 BERT sync : sync
DSX1 BERT sync count : 1
DSX1 BERT interval : 2
DSX1 BERT time remain : 2
DSX1 BERT total errs : 0
DSX1 BERT total k bits: 6165
DSX1 BERT errors (last): 0
DSX1 BERT k bits (last): 6165
Applique type is Channelized T1
Receiver has no alarms.
Cablelength is long gain36 0db
Framing is ESF, Line Code is B8ZS, Clock Source is Line.
Data in current interval (0 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
Router#
VIP
Router# show controllers t1 0/0/0 brief
T1 0/0/0 is up.
DSX1 BERT pattern : zeros
DSX1 BERT sync : sync
DSX1 BERT sync count : 1
DSX1 BERT interval : 2
DSX1 BERT time remain : 2
DSX1 BERT total errs : 0
DSX1 BERT total k bits: 43155
DSX1 BERT errors (last): 0
DSX1 BERT k bits (last): 43155
Applique type is Channelized T1
No alarms detected.
Cablelength is long gain36 0db
Framing is ESF, Line Code is B8ZS, Clock Source is Line.
Data in current interval (24 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
Router#
Note
When the T1 is under BERT (in the running state), its line state is down and the “Total Bit Errors” value
is not valid if the “Status” field is “Not Sync.”
is not valid if the “Status” field is “Not Sync.”