Cisco IDS 4210 10/100 SENSOR 规格指南

下载
页码 16
7
Use the following terminal settings:
Bits per second: 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow control: Hardware or RTS/CTS
Note
You can use a 180/rollover or straight-through patch cable
to
connect the sensor to a
port on a terminal server with
RJ-45 or hydra cable assembly connections
. For the
IDS-4215, connect the appropriate cable from the console port on the IDS-4215 to a
port on the terminal server. For all other sensors, use a M.A.S.H adapter (PN
29-4077-01) to connect the appropriate cable to a port on the terminal server.
Refer to
the Cisco Intrusion Detection System Appliance and Module Installation and
Configuration Guide Version 4.1 
for instructions on setting up a terminal server.
Step 5
Attach the network cables.
For the 4215, INT0 is the monitoring port, INT1 is the command and control port, and
INT2 through INT5 are the optional monitoring ports provided if you have the 4FE card
installed.
For the 4220/4230, the PCI card (int1) is now used as the command and control interface
and the onboard NIC (int0) is used as the sniffing interface.
Step 6
Power on the IDS appliance.
Modules
Services Module for Cisco Catalyst 6500 Series Switches
WS-SVC-IDSM2-K9
Cisco Catalyst 6500 Series Intrusion Detection System (IDSM-2) Services Module
Network Module for Cisco 2600/3600/3700 Series Routers
NM-CIDS-K9