Optimizing the speaker settings automatically (YPAO)
English
AD
V
A
NCED 
OP
ERA
TI
ON
4
Place the YPAO microphone at your listening 
position and connect it to the YPAO MIC jack 
on the front panel. 
Note
Place the YPAO microphone at your listening position (same 
height as your ears). We recommend the use of a tripod as a 
microphone stand. You can use the tripod screws to stabilize the 
microphone.
The following message appears on the front display.
Note
To cancel the operation, disconnect the YPAO microphone before 
starting the measurement.
5
To start the measurement, press ENTER.
The measurement will start in 10 seconds. It takes 
about 1 minute to perform the measurement.
Note
To cancel the measurement, press RETURN and then follow the 
procedure in “Error messages” (p. 44).
“Result Info.” appears on the front display when the 
measurement finishes.
Note
If “Error Info” appears, press the cursor key (
E
) to check the 
error message (p. 44).
6
To check the measurement result, press the 
cursor key (
E).
If “No Warning” appears on the front display, the 
measurement is properly completed.
Note
If any warning message (such as W-1) appears on the front 
display, see “Warning messages” (p. 45).
7
Press the cursor key (D) or RETURN.
8
To save the measurement results, use the 
cursor keys (
B / C) to select “Save” and 
press ENTER.
To finish the measurement without saving 
the result, use the cursor keys (
B / C) to 
select “Cancel” and press ENTER.
Note
You can change the YPAO settings (YPAO On/Off and YPAO 
Volume) in the “Setup” menu (p. 50).
9
Disconnect the YPAO microphone from this 
unit.
Notice
The YPAO microphone is sensitive to heat, so should not be 
placed anywhere where it could be exposed to direct sunlight or 
high temperatures (such as on top of AV equipment). 
YPAO MIC
YPAO MIC jack
YPAO microphone at 
listening position
Ear 
height
[ENTER]:Start
YPAO
Result Info.
YPAO( A
No Warning
YPAO( A
[ENTER]:Save
YPAO( A
[ENTER]:Cancel
YPAO( A
Disconnect MIC