Troubleshooting
If a problem should arise, first check the following:
1. Are the connections correct?
2. Is the set being operated as described in the owner’s manual?
3. Are the other devices operating properly?
If this unit does not operate properly, check the corresponding symptoms in this section.
If the symptoms do not match any of those described here, consult your dealer as it could be due to a fault in this unit. In this case, disconnect the power
immediately and contact the store where you purchased this unit.
Power does not turn on / Power is turned off
Symptom
Cause / Solution
Page
Power is not turned on.
0
Check whether the power plug is correctly inserted into the power outlet.
Power automatically turns
off.
0
The Auto Standby mode is on. When approx. 30 minutes pass with no audio input and no operations on
the unit, this unit automatically enters the standby mode. To turn off the Auto Standby mode, press the
SOURCE DIRECT button for 5 seconds or longer.
Power turns off and the
power indicator flashes in
red approx. every 0.25
seconds.
0
The protection circuit has been activated due to a rise in temperature within this unit. Turn the power off,
wait about an hour until this unit cools down sufficiently, and then turn the power on again.
0
Please re-install this unit in a place having good ventilation.
0
Check the speaker connections. The protection circuit may have been activated because speaker cable
core wires came in contact with each other or a core wire was disconnected from the connector and
came in contact with the rear panel of this unit. After unplugging the power cord, take corrective action
such as firmly re-twisting the core wire or taking care of the connector, and then reconnect the wire.
0
Turn down the volume and turn on the power again.
0
This unit’s amplifier circuit has failed. Unplug the power cord and contact our customer service center.