Sony FE 70-200 mm f/ 2.8 GM OSS Lens 用户指南

下载
页码 56
4-15
SAL75300 (4.5-5.6/75-300) (75-300mm F4.5-5.6)
4)
Adjust the back washer thickness according to the result of step 3). (Refer to Table 4-4-2 and Fig.4-4-5.)
Note:
Use the micrometer gauge (or slide gauge) to measure the back washer thickness.
If focus error is a negative value: Decrease back washer thickness by error amount to increase flange back.
If focus error is a positive value:
Increase back washer thickness by error amount to decrease flange back.
5)
Calculate the adjustment washer thickness using the following formula, and replace the adjustment washer.
(Refer to Table 4-4-2 and Fig.4-4-5.)
Coupler adjustment washer thickness = Back washer thickness - 0.25 mm
Back washer
Parts No.
T (mm)
A
2-698-455-01
0.05
B
2-698-456-01
0.07
C
2-698-457-01
0.1
D
2-698-458-01
0.2
E
2-698-459-01
0.5
Coupler adjustment washer
Parts No.
T (mm)
A
2-684-057-01
0.05
B
2-684-058-01
0.07
C
2-684-059-01
0.1
D
2-684-060-01
0.2
E
2-684-061-01
0.5
Table 4-4-2
Fig.4-4-5
6)
Install the back washer and coupler adjustment washer, and perform “4-4-1. Flange Back (f’F) Check” again.
A
B
A
B
Coupler Adjustment Washer
Back Washer