Inspect the generator regularly, and promptly 
repair or replace all worn, damaged or defective 
parts using only factory-approved parts.
Before performing any maintenance on the gen-
erator, disconnect its battery cables to prevent 
accidental start-up. Disconnect the cable from the 
battery post indicated by a NEGATIVE, NEG or (–) 
first. Reconnect that cable last.
Never use the generator or any of its parts as a 
step. Stepping on the unit can stress and break 
parts, and may result in dangerous operating con-
ditions from leaking exhaust gases, fuel leakage, 
oil leakage, etc.
 ELECTRICAL HAZARDS 
All generators covered by this manual produce 
dangerous electrical voltages and can cause fatal 
electrical shock. Utility power delivers extremely 
high and dangerous voltages to the transfer switch, 
as does the standby generator. Avoid contact with 
bare wires, terminals, connections, etc., on the gen-
erator as well as the transfer switch, if applicable. 
Ensure all appropriate covers, guards and barriers 
are in place before operating the generator. If work 
must be done around an operating unit, stand on 
an insulated, dry surface to reduce shock hazard.
Do not handle any kind of electrical device while 
standing in water, while barefoot, or while hands 
or feet are wet. DANGEROUS ELECTRICAL 
SHOCK MAY RESULT.
If people must stand on metal or concrete while 
installing, operating, servicing, adjusting or repair-
ing this equipment, place insulative mats over a 
dry wooden platform. Work on the equipment only 
while standing on such insulative mats.
The National Electrical Code (NEC), Article 250 
requires the frame and external electrically con-
ductive parts of the generator to be connected to 
an approved earth ground and/or grounding rods. 
This grounding will help prevent dangerous electri-
cal shock that might be caused by a ground fault 
condition in the generator set or by static electric-
ity. Never disconnect the ground wire.
Wire gauge sizes of electrical wiring, cables and 
cord sets must be adequate to handle the maxi-
mum electrical current (ampacity) to which they 
will be subjected.
Before installing or servicing this (and related) 
equipment, make sure that all power voltage 
supplies are positively turned off at their source. 
Failure to do so will result in hazardous and pos-
sibly fatal electrical shock.
Connecting this unit to an electrical system nor-
mally supplied by an electric utility shall be by 
means of a transfer switch so as to isolate the 
generator electric system from the electric utility 
distribution system when the generator is operat-
ing. Failure to isolate the two electric system power 
sources from each other by such means, will result 
in damage to the generator and may also result 
in injury or death to utility power workers due to 
backfeed of electrical energy.
Generators installed with an automatic transfer 
switch will crank and start automatically when 
normal (UTILITY) source voltage is removed or is 
below an acceptable preset level. To prevent such 
automatic start-up and possible injury to person-
nel, disable the generator’s automatic start circuit 
(battery cables, etc.) before working on or around 
the unit. Then, place a “Do Not Operate” tag on 
the generator control panel and on the transfer 
switch.
In case of accident caused by electric shock, imme-
diately shut down the source of electrical power. If 
this is not possible, attempt to free the victim from 
the live conductor. AVOID DIRECT CONTACT 
WITH THE VICTIM. Use a nonconducting imple-
ment, such as a dry rope or board, to free the 
victim from the live conductor. If the victim is 
unconscious, apply first aid and get immediate 
medical help.
Never wear jewelry when working on this equip-
ment. Jewelry can conduct electricity resulting in 
electric shock, or may get caught in moving com-
ponents causing injury.
 FIRE HAZARDS 
Keep a fire extinguisher near the generator at all 
times. Do NOT use any carbon tetra-chloride type 
extinguisher. Its fumes are toxic, and the liquid 
can deteriorate wiring insulation. Keep the extin-
guisher properly charged and be familiar with its 
use. If there are any questions pertaining to fire 
extinguishers, consult the local fire department.
 EXPLOSION HAZARDS 
Properly ventilate any room or building housing 
the generator to prevent build-up of explosive gas.
Do not smoke around the generator. Wipe up any 
fuel or oil spills immediately. Ensure that no com-
bustible materials are left in the generator com-
partment, or on or near the generator, as FIRE or 
EXPLOSION may result. Keep the area surround-
ing the generator clean and free from debris.
These generator sets may operate using one of 
several types of fuels. All fuel types are potentially 
FLAMMABLE and/or EXPLOSIVE and should be 
handled with care. Comply with all laws regulat-
ing the storage and handling of fuels. Inspect the 
unit’s fuel system frequently and correct any leaks 
immediately. Fuel supply lines must be prop-
erly installed, purged and leak tested according to 
applicable fuel-gas codes before placing this equip-
ment into service.
Diesel fuels are highly FLAMMABLE. Gaseous 
fluids such as natural gas and liquid propane 
(LP) gas are extremely EXPLOSIVE. Natural gas 
is lighter than air, and LP gas is heavier than air; 
install leak detectors accordingly.