Alpha 360 Co. LTd 200801 用户手册

下载
页码 2
operating instructions of Alpha 360 z-Stick 
 
Operating instructions:   
   
The Z-Stick operates in three distinct modes: Inclusion-Mode, Removal-Mode and SerialAPI- 
Mode. Both Inclusion-Mode and Removal-Mode require the Z-Stick to be unplugged from the   
USB connector of the host, while SerialAPI-Mode requires the Z-Stick to be plugged into the   
USB connector of the host.   
   
Inclusion-Mode:  
1.    To initiate Inclusion-Mode, unplug the Z-Stick from the USB connector and then tap the   
button.    (The LED will blink slowly.)   
Note: While in Inclusion-Mode, the Z-Stick is in perpetual inclusion.    There is no need to   
press the button on the Z-Stick again to include each new device.       
2.    To include a new Z-Wave device into the network, simply go to the device with the Z- 
Stick and press the button on the device you wish to include.    (The LED on the Z-Stick   
will blink fast during a network neighbor discovery and stay solid for 3 seconds to   
indicate successful inclusion of the device into the network.)   
3.    The LED will then return to blinking slowly, indicating readiness for further device   
inclusions.    Repeat step 2 for each device as you wish to include.     
4.    Tap the Z-Stick button to turn it off.       
   
Removal-Mode:  
1.  To initiate Removal-Mode, unplug the Z-Stick from the USB connector.  Then press 
and  
hold down the button for approximately 3 seconds.    (The LED will transition from   
blinking slowly to blinking fast.)   
Note: While in Removal-Mode, the Z-Stick is in perpetual removal.    There is no need to   
press the button on the Z-Stick again to remove each device.       
2.    To remove a Z-Wave device from the network, simply go to the device with the Z-Stick   
and press the button on the device you wish to remove.    (The LED on the Z-Stick will   
immediately stay solid for 3 seconds to indicate successful removal from the network.)   
3.    The LED will then return to blinking fast, indicating readiness for further device   
removals.    Repeat step 2 for each device as you wish to remove.       
4.    Tap the Z-Stick button to turn off.       
   
   
SerialAPI-Mode:   
1.    To initiate SerialAPI-Mode, plug the Z-Stick into the USB connector of the host.   
Note: While in SerialAPI-mode, the Z-Stick acts as a Z-Wave adapter and responds to   
commands sent through USB by the host processor software.    Pressing the Z-Stick   
button will not have any effect while in SerialAPI-Mode.