Diagnostics Operations 
 
Getting Started 
26 
 
 
In  case  of  wired  connection,  check  the  cable  connection  between 
the display tablet and the VCI device. 
 
Check  if  the  green  LED  on  the  VCI  device  is  illuminated  for 
Bluetooth, Ethernet, or USB. 
 
Check  if  the  Error  LED  on  the  VCI  device  is  on,  this  may  indicate 
there is a communication error between the devices, in this case try 
re-establishing  the  connection  again;  if  this  does  not  work,  there 
may be a hardware problem with the device, in this case contact for 
technical support. 
B. 
If the VCI device is unable to establish a communication link, a prompt 
message  displays  with  check  instructions.  The  following  conditions  are 
the possible causes for this massage to display: 
 
The VCI device is unable to establish a communication link with the 
vehicle. 
 
You
’ve selected a system for testing that the vehicle is not equipped 
with. 
 
There is a loose connection. 
 
There is a blown vehicle fuse. 
 
There is a wiring fault on the vehicle, or the data cable or adapter. 
 
There is a circuit fault in the data cable or adapter. 
 
Incorrect vehicle identification was entered. 
4.2  Getting Started 
Prior  to  first  use  of  the  Diagnostics  application,  the  VCI  device  must  be 
synchronized  with  the  MaxiSys  Display  Tablet  to  establish  a  communication 
link. See 
 on page 90.
 
4.2.1  Vehicle Menu Layout 
When the VCI device is properly connected to the vehicle, and paired to the 
MaxiSys Display Tablet, the platform is ready to start vehicle diagnosis. Tap on 
the Diagnostics application button on the MaxiSys Job Menu, the screen then 
opens the Vehicle Menu.