RSI VIDEOTECHNOLOGIES SE00 用户手册

下载
页码 3
www.videofied.com
Mounting
Use proper tools and hardware.
Mount where siren can be heard by occupants.
Mount out-of-reach of intruders to help prevent  
  disabling of unit.
1
  Remove batteries.
2
  Hold unit up   
 
against mounting  
 
 
 
 
surface and mark  
 
the three mounting   
 holes.
3
  Drill pilot holes  
 
and  install anchors    
 
 
 
where needed.
4
  Place unit on mounting surface so mounting holes  
 
line up with pilot holes/anchors and secure unit with  
 
appropriate screws.
5
  Install batteries, observing correct polarity.
6
  Attach front cover.
Electrical Data
Panel Compatibility 
XL, Visio, XT, XTIP
Power requirements 
Four 1.5 V Alkaline Batteries
      Nominal Voltage 
6V
      Low Battery Limit 
4.2V
      Battery type 
Energizer Alkaline LR20, D size
      Battery life 
Up to 4 years
RF technology 
S
2
View
®
Radio type 
Spread Spectrum Bidirectional
Operating frequency 
915 MHz 
Transmission security 
AES encryption algorithm
Supervision 
Polled signal every 8 minutes
Antenna Integrated
Tamper detection 
Wall and cover tampered
Speaker impedance 
4 ohms
Output level 
110 dB @ 1 meter
Output duration 
Configured in Control Panel
Built-in sounder 
Emits entry/exit delay beeps, alarms
Operating temperature  
-10°/+40°C (14°/104°F)
Maximum relative humidity 
70%, non-condensing
Approvals     
FCC Part 15C
Physical Data
Material ABS—ULV0
Dimensions (LxWxD) 
 280 mm x 158 mm x 57 mm 
 
11 in. x 6-1/4 in. x 2-1/4 in. 
Weight 
740 g/26 oz.(without batteries)
Installation/Mounting
Siren/Base 
Two screws secure siren to base; three screws  
 
secure siren base to mounting surface. 
Mounting Holes
Indoor Siren SE601
I N S T A L L A T I O N   D A T A   S H E E T