Selex ES SPA F567DHDE-HP 用户手册

下载
页码 60
 
SELEX Communications 
Information contained in this document may not be used, applied or reproduced for any purpose unless agreed 
by SELEX Communications S.p.A. in writing
 
28
 
   July 2010 
 
 
4W+E/M line usage 
PIN  
4W+E/M 
M (+) 
Mouth signal + 
M (-) 
Mouth signal - 
E (+) 
Ear Signal + 
AF_OUT (-) 
600 Ohm Balanced OUT AF 
AF_OUT (+) 
600 Ohm Balanced OUT AF 
E (-) 
Ear Signal - 
AF_IN (-) 
600 Ohm Balanced IN AF 
AF_IN (+) 
600 Ohm Balanced IN AF 
 
E/M pin usage 
PIN   Balanced Unbalanced 
M (+)  Mouth signal + 
Mouth signal 
M (-) 
Mouth signal - 
not connected 
E (+) 
Ear Signal + 
Ear Signal 
E (-) 
Ear Signal - 
not connected 
 
E/M Hardware Line settings 
The four Mouth signals share the same hardware configuration. The four Ear signals share the same 
hardware configuration. For unbalanced settings connect the two communicating entities to the same 
ground. 
E/M Type I Interface Model
 
E/M Type I is the original E/M lead signaling arrangement and it is the most common interface type in 
North America. The following diagram displays the sent signal states for active/not active signaling. 
The RBS grounds its M−lead to signal a seizure. The other device applies battery to its M−lead to 
signal a seizure. Prod-El SRB expect to see active conditions on the E−lead and signal active to the 
remote device on M−lead. 
 
E/M Type II Interface Model
 
SRB side