Quectel Wireless Solutions Company Limited 201807EG95NA 用户手册

下载
页码 87
LTE  Module  Series 
                                                                                                  EG95  Hardware  Design
 
 
EG95_Hardware_Design                                                                                                                              59 / 81 
 
 
 
Voltage drop during 
burst transmission 
Maximum power control 
level on EGSM900 
 
 
400 
mV 
I
VBAT
 
Peak supply current 
(during transmission 
slot) 
Maximum power control 
level on EGSM900 
 
1.8 
2.0 
USB_VBUS 
USB connection 
detection 
 
3.0 
5.0 
5.25 
 
6.3. 
Operation and Storage Temperatures 
 
The operation and storage temperatures are listed in the following table. 
 
Table 28: Operation and Storage Temperatures 
Parameter 
Min. 
Typ. 
Max. 
Unit 
Operation Temperature Range 
1)
 
-
35 
+25 
+75 
ºC 
Extended Temperature Range 
2)
 
-
40 
 
+85 
ºC 
Storage Temperature Range 
-
40 
 
+90 
ºC 
 
 
1. 
1) 
Within operation temperature range, the module is 3GPP compliant.   
2.     
2) 
Within  extended  temperature  range,  the  module  remains  the  ability  to  establish  and  maintain  a 
voice, SMS, data transmission, emergency call, etc. There is no unrecoverable malfunction. There 
are also no effects on radio spectrum and no harm to radio network. Only one or more parameters 
like  P
out
  might  reduce  in  their  value  and  exceed  the  specified  tolerances.  When  the  temperature 
returns to the normal operating temperature levels, the module will meet 3GPP specifications again. 
 
 
 
 
 
 
 
 
NOTES