Andrew Wireless System M78517E19P 用户手册

下载
页码 55
 
4. Commissioning
 
Page 36 
 
MF0150A2A.doc                             Manual for ION-M7P/85P/17EP/19P 
 
 
5.  Fasten the insulator by screwing the 
backshell tight onto it. Use a spanner 
with opening 32 to screw the 
backshell tight (no gap). 
6.  Place the appropriate seal parts (with 
one groove for one contact or two 
grooves for two contacts) over the 
cable(s) and push them into the 
backshell. 
 
7.  Bring the plastic ring over the cable(s), push it into the backshell and compress 
the seals and plastic ring by screwing the clamp ring tight (no gap) using a 
spanner with opening 20. *** 
8.  Connect the plug to the optical-fibre 
connector of the Remote Unit, again 
by fitting a stamp on the plug into the 
groove of the connector.  
9.  To lock the connector, push the black 
locking ring forward.****  
***  For disassembling, release the clamping ring and remove the seals and the plastic ring first. 
****  Locking mechanism: The system of locking the plug is based on a “push-pull” mechanism. The 
locking ring has to be pushed forward to lock the connector and pulled back to free the 
connection. 
 
Seals with 
one groove 
Groove 
Push forward to lock, pull 
back to free connection 
No gap 
Screw tight until gap is closed