Control Connector (RS485 / RS232) 
 
This 8-pin male connector (type: Binder Series 712) primarily supports control of the 
Extension Unit via RS485 bus. 
  
 
 
PIN Assignment 
1 not 
connected 
2 RS232 
Rx 
3 RS232 
Tx 
4 not 
connected 
5 GND 
(RS232) 
6 RS485 
R+/D+ 
7 RS485 
GND 
8 RS485 
R-/D- 
figure 3-5 RS485 connector 
table 3-2 RS485 connector, pin assignment 
 
3.2.3.  Grounding 
 
Grounding must be carried out. Connect an earth-bonding cable to the grounding 
connection provided at the outside of the Remote Unit (see  chapter  3.2.2 
Connections
). Do not use the grounding connection to connect external devices. 
 
 
 
figure 3-6 Grounding bolt 
figure 3-7 Grounding bolt, schematic view 
 
After loosening the hex nut, connect the earth-bonding cable between the two 
washers as illustrated in the figures above. Then, fasten all parts again with the hex 
nut. 
 