Telecell Installation Manual 
Installation 
TL-006175-PR Issue 5 © Telensa Ltd 2018 
 
 
  Page 17 
 
LOW PROFILE                          
 
 
 
 
    ANT-S-LP-A 
 
 
    ANT-S-LP-E 
915MHz low profile (SMA) 
 
868MHz low profile (SMA) 
EASY FIT                       
 
   ANT-S-EF-M 
868MHz and 915MHz 
easy fit (SMA) 
 
1) 
These Telecells are fitted inside the fixture securely, without compromising the 
other components and positioned in a manner in keeping with the natural 
workings.  
Note:  This must be wired to the incoming supply and outgoing ballast/driver 
along with the dimming wires as in section 2.2.2. 
2) 
Connect the antenna to the Telecell. 
Note:  DO NOT OVER TIGHTEN RF CONNECTOR (0.3 – 0.6Nm). 
3) 
Turn on the mains supply to the Telecell and observe the Power On / DIM / Off 
test cycle as described in section 1.7.1. It will turn on for 50 seconds, then turn off. 
If dimmable: on 25 seconds, dim 25 seconds, then turns off. 
4) 
Record the necessary data as detailed under section 1.7. Data capture will be 
dependent on available tools, for example: paper based or import via PDA. 
5) 
Affix the Telecell labels described in section 1.7 as necessary. 
 
2.1.1 
Two-Part Mounting 
The maximum screw insertion depth is 12mm. Base mounting lugs are snap off, if 
required, to enable mounting in confined spaces. 
2.1.2 
Two-Part Antenna Connection 
The Two-Part version antenna connection uses an SMA connector, the plug is fitted to the 
Telecell. Additional antenna cabling must use 50ohm coax with low loss at the operating 
frequency (868 MHz for ETSI variants, 915MHz for FCC variants). It is recommended to 
contact Telensa before using a longer antenna cable.