Elec-Tech International Co. Ltd. 90600120 用户手册

下载
页码 3
THANK YOU 
We appreciate the trust and confidence you have placed in Commercial Electric through the purchase of this motion 
sensor module. We strive to continually create quality products designed to enhance your home. Visit us online to see 
our full line of products available for your home improvement needs. Thank you for choosing Commercial Electric!
Warranty
WHAT IS COVERED
The manufacturer warrants this product to be free from defects in materials and workmanship for 
a period of five (5) years from date of purchase. This warranty applies only to the original consumer 
purchaser and only to products used in normal use and service. If this product is found to be defective, 
the manufacturer’s only obligation, and your exclusive remedy, is the repair or replacement of the 
product at the manufacturer’s discretion, provided that the product has not been damaged through 
misuse, abuse, accident, modifications, alterations, neglect, or mishandling.
WHAT IS NOT COVERED
This warranty shall not apply to any product that is found to have been improperly installed, set-up, or 
used in any way not in accordance with the instructions supplied with the product. This warranty shall 
not apply to a failure of the product as a result of an accident, misuse, abuse, negligence, alteration, 
faulty installation, or any other failure not relating to faulty material or workmanship. This warranty 
shall not apply to the finish on any portion of the product, such as surface and/or weathering, as this is 
considered normal wear and tear.
The manufacturer does not warrant and specifically disclaims any warranty, whether express or 
implied, of fitness for a particular purpose, other than the warranty contained herein. The manufacturer 
specifically disclaims any liability and shall not be liable for any consequential or incidental loss or 
damage, including but not limited to any labor / expense costs involved in the replacement or repair of 
said product.
Contact the Customer Service Team at 1-877-527-0313 or visit www.HomeDepot.com.
Questions, problems, missing parts? Before returning to the store,  
call Commercial Electric Customer Service 
8 a.m. - 7 p.m., EST, Monday - Friday, 9 a.m. - 6 p.m., EST, Saturday
1-877-527-0313
HOmEDEpOT.COm
Use and Care GUide
MOTiOn sensOr MOdULe
item #1000000000 
Model #
90600120
Care and Cleaning
CaUTiOn: Before attempting to clean the sensor, disconnect the power to the fixture by turning the breaker 
off or removing the fuse from the fuse box. 
…
…
Clean the sensor with a soft, dry cloth.
…
…
Do not use cleaners with chemicals, solvents, or harsh abrasives.
…
…
Do not use liquid cleaner on the sensor.
Pre-installation
Before beginning assembly, installation or operation of the product, make sure all parts are present. 
Compare parts with the package contents list. If any part is missing or damaged, do not attempt to 
assemble, install or operate the product. Contact customer service for replacement parts.
nOTe: Keep your receipt and these instructions for proof of purchase.
If you are unfamiliar with electrical installations, we recommend you contact a qualified electrician to do 
the installation.
TOOlS REqUIRED
pACKAgE CONTENTS
part
Description
quantity
A
Motion Sensor Module
1
HARDWARE INClUDED
part
Description
quantity
AA
Locknut (3/4 in.)
1
BB
Lock Washer (3/4 in.)
1
CC
Locknut (1/2 in.)
1
DD
Lock Washer (1/2 in.)
1
EE
Wire Connectors
3
FF
Male to Male Connector
1
installation
WarninG: RISK OF ELECTRIC SHOCK. Ensure the electricity to the wires you are working on is shut off. 
Either remove the fuse or turn off the circuit breaker before beginning assembly or installation.
nOTiCe: This motion sensor module works with direct hard wired LED and fluorescent light fixtures as well as 
with selected Commercial Electric linkable plug-in LED light fixtures.  Visit HomeDepot.com for a list of compatible 
Commercial Electric linkable plug-in fixtures. 
nOTiCe: The motion sensor can be used for fixtures installed up to 18 feet high.
1
preparing the fixture
…
…
Remove the diffuser/lens to allow access to the 
fixture wiring.
…
…
Remove the knockout  
where you wish to mount  
the sensor module.
installing for Use with direct Wired Fixtures
2
Determining the knockout size
…
…
Choose the appropriate knockout size for 
your fixture, either 3/4” or 1/2”, and use only 
the locknut and lock washer for that size.
4
Connecting the sensor module to the fixture
…
…
Insert the threaded end of the sensor module (A) completely 
into the selected knockout hole and through the lock washer 
(BB/DD). Then tighten the locknut (AA/CC) securely onto the 
threaded end of the sensor module (A).
nOTe: For a firm fit, gently use pliers to tighten the locknut (AA/CC). 
3
Feeding the wires
…
…
Feed the electrical connection wires from 
the sensor module (A) through the selected 
knockout hole and then through the lock 
washer (BB/DD) followed by the locknut  
(AA/CC).
nOTe: The lock washer (BB or DD) and 
locknut (AA or CC) should be on the inside of 
the fixture wall with the wires coming through 
the center of each.
5
making the electrical connections
…
…
Connect the hot (black) wire from the sensor (A) to the black 
wire from the electrical box. 
…
…
Connect the neutral (white) wire from the sensor (A) to the 
white wire from the fixture and the white wire from the 
electrical box.
…
…
Connect the secondary live wire 
(red) from the sensor (A) to the live 
wire (black) from the fixture.
…
…
Cover the three wire connections 
using the wire connectors (EE).
nOTiCe: The green wire from the fixture 
should continue to be connected to the 
grounding wire from the electrical box.
6
Attaching the diffuser to the housing
…
…
Replace the diffuser/lens on the light fixture.
…
…
Restore power to the electrical box. 
…
…
Turn on the light switch to activate the 
fixture.
installing for use with selected Commercial electric linkable 
plug-in Led light fixtures
1
preparing the fixture
…
…
Unplug the power cord from the 
electrical outlet and from the light 
fixture.
2
Connecting the sensor module to the 
fixture
…
…
Insert the small male-to-male connector (FF) to 
the Power Out side of the sensor module (A).
…
…
Push the other end of the male-to-male 
connector (FF) into the Power end of the fixture.
…
…
Make sure both connections fit securely.
nOTe: The sensor module (A) notes which end is 
Power In and which is Power Out.
3
Turning on the power
…
…
Insert the power cord firmly into the Power In end of 
the sensor module (A).
…
…
Plug the power cord into the electrical outlet.
…
…
Turn on the light fixture.
adjusting the Motion sensor
safety information
WarninG: Carefully read and understand the 
information given in this manual before beginning the 
assembly and installation. Failure to do so could lead 
to electric shock, fire, or other injuries which could be 
hazardous or even fatal.
WarninG: Ensure the electricity to the wires you 
are working on is shut off. Either remove the fuse or 
turn off the circuit breaker.
FCC ID:XZH-90600120
nOTiCe: This device complies with Part 15 of the FCC 
Rules. Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, and (2) 
this device must accept any interference received, including 
interference that may cause undesired operation.
CaUTiOn: Changes / modifications not approved by the 
responsible party could void the user’s authority to operate 
the equipment. 
Wire Strippers
Safety Goggles
Ladder
Gloves
Pliers
installing for Use with direct Wired Fixtures (continued)
Troubleshooting
WarninG: Before doing any work on the motion sensor module, disconnect power to the light fixture.
Minor problems often can be fixed without the help of an electrician.
installing for use with selected Commercial electric linkable 
plug-in Led light fixtures (continued)
AA
A
EE
FF
Detection area
…
…
The motion detection 
area can be adjusted 
by selecting the 
combination of settings 
on the DIP switches 
for the desired motion 
detection area.
detection area
Coverage By install Height
DIP 1 DIP 2
10 ft. Ceiling
9 ft. Ceiling
8 ft. Ceiling
I
n
n
100%
43 ft. x 10 ft.
40 ft. x 9 ft.
39 ft. x 8 ft.
II
n
75%
36 ft. x 10 ft.
34 ft. x 9 ft.
33 ft. x 8 ft.
III
n
50%
26 ft. x 10 ft.
23 ft. x 9 ft.
23 ft. x 8 ft.
IV
10%
7 ft. x 10 ft.
7 ft. x 9 ft.
7 ft. x 8 ft.
DIP 3
DIP 4
I
n
n
5 sec.
II
n
90 sec.
III
n
5 min.
IV
15 min.
DIP 5
DIP 6
I
n
n
Disable
II
n
50 lux.
III
n
10 lux.
IV
2 lux.
I  -   100%
II  -   75%
III -   50%
IV -   10%
I  -   5 sec.
II  -   90 sec.
III -   5 min.
IV -   15 min.
I  -   Disable
II  -   50 lux.
III -   10 lux.
IV -   2 lux.
Motion Sensor 
Detection Area
Hold-time
Daylight Sensor  
Light Level
DIP 1
DIP 2
DIP 3
DIP 4
DIP 5
DIP 6
n
n
n
n
75%
5 minutes
Disabled
The sensor comes from the factory with the following settings:
…
…
Detection Area: 75%
…
…
Hold Time: 5 Minutes
…
…
Daylight Sensor: Photocell Disabled
To adjust the settings, simply move the DIp switches to the settings you prefer.
Hold-time
…
…
Hold-time is the time period the light will remain 
on after the person has left the detected area. 
The amount of time the light remains on can be 
adjusted by selecting the combination of settings 
on the DIP switches for the desired hold-time.
Daylight sensor
…
…
The daylight threshold can be adjusted by 
selecting the combination of settings on the DIP 
switches to determine the level of darkness when 
the light will turn on automatically.
Problem
Possible Cause
solution
The fixture will not light.
The power is off.
Ensure the power supply and circuit breaker are both in the on position.
There is a bad connection. Check to ensure proper wire connections are made. Contact a qualified electrician.
The motion sensor module 
is mounted higher than 
18 ft.
Mount the fixture with the motion sensor module at 18 ft. or lower.
The fuse blows or the 
circuit breaker trips when 
the light is turned on.
The wires are crossed 
or the power wire is 
grounding out.
Check the wire connections. 
Contact a qualified electrician or call Commercial Electric customer service  
1-877-527-0313.
The light is not staying on 
long enough after the last  
motion is detected.
The hold-time setting 
needs to be adjusted.
Factory setting is a 5 minute hold time. To increase the time 
period the light remains on, please refer to the Adjusting the 
Motion Sensor section of the instruction manual to adjust the 
4th dip switch to the preferred setting.
The light is staying on too 
long after the last motion is 
detected.
The hold-time setting 
needs to be adjusted.
Factory setting is a 5 minute hold time. To decrease the time 
period the light remains on, please refer to the Adjusting the 
Motion Sensor section of the instruction manual to adjust the 
3rd and 4th dip switches to the preferred setting.
The motion sensor is not 
detecting motion in a large 
enough area.
The motion sensor needs 
to be adjusted.
To increase the motion detection area, please refer to the 
Adjusting the Motion Sensor section of the instruction manual 
to adjust the 1st and 2nd dip switches to the preferred setting.
The motion sensor is 
detecting motion in too 
large an area.
The motion sensor needs 
to be adjusted.
To decrease the motion detection area, please refer to the 
Adjusting the Motion Sensor section of the instruction manual 
to adjust the 1st and 2nd dip switches to the preferred setting.
The motion sensor is 
detecting motion during 
daylight hours and turning 
the light on when I do not 
need it on.
The daylight sensor needs 
to be adjusted.
Ensure the 5th and 6th dip switches are set to detect light at 
the 50 lux, 10 lux or 2 lux settings. Please refer to the Adjusting 
the Motion Sensor section of the instruction manual to adjust 
the 5th and 6th dip switches to the preferred setting.
The motion sensor is not 
detecting motion and 
turning the light on during 
daylight hours when I 
need it to.
The daylight sensor needs 
to be adjusted.
Ensure the 5th and 6th dip switches are set at “disable”. This 
will allow the light to turn on when motion is detected at any 
light level. Please refer to the Adjusting the Motion Sensor 
section of the instruction manual to adjust the 5th and 6th dip 
switches to the preferred setting.
BB
CC
DD
Knockout holes
FF
A
AA/CC
AA/CC
IV
15 min.
I
n
n
5 sec.
II
n
90 sec.
I
n
n
100%
I
n
n
Disable
II
n
50 lux.
III
n
10 lux.
IV
2 lux.
III
n
50%
IV
10%
A
FCC ID:  XZH-9050102016
A
BB/DD
A
DIP Switches
A
BB/DD
FF
A
A
Black
BB/DD
AA/CC
Red
EE
White
Black