144 Detail program description - Phase settings | Winged models
Example:
Phase  1
Phase  2
Phase  3
Phase  4
Phase  5
Name
Timer
Sw. time
Motor
0.1s
yes
0.1s
yes
1.1s
yes
0.1s
yes
0.1s
¾
Normal
Launch
Dist.
yes
The switchover time from any other phase to Phase 1 
«normal» will take 2.2 s. 
The time for a switchover from, for example, Phase 1 
to Phase 3, is set to 1.1 s and the time for a switchover 
from Phase 1 or 3 to Phase 2 "Launch" is 1.5 s.
Such asymmetric transition times can be useful when, 
e.g. switching between extremely different fl ight 
phases, such as between aerobatics and normal fl ight.
A simultaneous tap on the 
cd or ef keys of the 
right touch pad (CLEAR) will reset the time in the 
currently active value fi eld back to 0.1.
Note:
The "switch time" set here applies uniformly to all 
settings that are specifi c to fl ight phases, and thus 
to all mixers activated in the »Wing mixers« menu, 
see page 160. Accordingly, the transition between 
fl ight phase-specifi c mixers does not occur abruptly. 
However, if individual servos are to be switched 
without a delay then these can be defi ned accordingly 
in the »Non-delayed chan« menu (see page 151).