Graupner GmbH & Co. KG MC-20 用户手册

下载
页码 324
153
Detail program description - Timers (general)
   "Flight tim"
This timer is especially for measuring fl ight time: it 
can be started with an assigned switch and stopped 
(once the switch has been re-opened) on the basic 
display with a tap on the center 
ESC
 key of the left 
touch pad. Once in a stopped state, it can be reset to 
its starting value with a simultaneous tap on the 
cd
or
ef keys of the right touch pad at the same time 
(CLEAR). 
If you wish to assign a control switch, you must fi rst 
defi ne the switch on the»Control switch« menu and 
specify the switching point along the travel of the 
transmitter control. As an example, the timer can then 
be started by "opening the throttle" or by opening the 
throttle limiter for helicopter models.
Note:
The combination of the fl ight time timer and 
stopwatch means that you can glance at the display 
at any time and see how long you have been fl ying 
since the timers were started, plus the total motor 
runtime within this particular period of fl ight time.
  "Time frame"
The time frame timer is intended primarily for use 
by competition pilots, who are frequently given a 
timeframe within which they must complete certain 
tasks. The timer is started in precisely the same way 
as the fl ight time timer. To stop the timer, fi rst ensure 
the timer switch is at its OFF position. Then touch and 
hold the 
cd or ef selection keys then touch the 
center
ESC
 key.
  Switch assignment
Use the 
f selection key of the left or right touch 
pad to move the marker frame next to the triangle 
as shown in the screen image shown below to the 
rightmost column of the relevant line:
Model time
Batt.   time
Timer
–––
12:34h
1:23h
0:00
0:00
0s
0s
–––
–––
Alarm
Timer
Top   : Stop watch
Centr : Flight tim
Here, you assign a switch as described in the section 
"Assigning transmitter controls, switches and control 
switches" (page 56).
Typical application:
The "stop watch" and "fl ight timer" are both to be 
started simultaneously using the C1 stick as soon as 
a user-defi ned switching point is exceeded.
For this purpose, defi ne a control switch, e.g. "C1", in 
the »Control switch« menu, page 135. To complete 
the procedure, you select this from the expanded 
switches (see the section "Assigning transmitter 
controls, switches and control switches" on page 56) 
and assign it to both these lines:
Model time
Batt.   time
Timer
–––
12:34h
1:23h
0:00
0:00
0s
0s
Alarm
Timer
G1
G1
Top  : Stop watch
Centr: Flight tim
The stopwatch will now stop when the stick is below 
the switching point and resume running above the 
switching point. The same is not true for the fl ight 
time timer, however, which also starts the fi rst time 
the switching point is exceeded. It can be stopped 
(with a tap on the center 
ESC
 key of the left touch 
pad) only once the stopwatch is stopped; it can then 
be reset to its starting value with a simultaneous 
tap on the 
cd or ef keys of the right touch pad 
(CLEAR).
   Switchover between "forward" and "backward"
Timer runs forwards (stopwatch function)
Following switch assignment, if the stopwatch shown 
on the basic display is started with the initial value of 
"0:00", then it will run forwards for max. 180 min and 
59 s and then restart from 0:00.
Timer runs backwards (countdown function)
In the – left – minutes fi eld, select a start time between 
0 and 180 min …
Model time
Batt.   time
Timer
–––
12:34h
1:23h
180
:00
0:00
0s
0s
–––
–––
Alarm
Timer
Top   : Stop watch
Centr : Flight tim
… and in the – right – seconds fi eld, select a start time 
between 0 and 59 s (or any combination of these):
Model time
Batt.   time
Timer
–––
12:34h
1:23h
180:
59
0:00
0s
0s
–––
–––
Alarm
Timer
Top   : Stop watch
Centr : Flight tim
Procedure
Select the desired input fi eld with the 
1. 
ef
selection keys of the left or right touch pad.
Now tap on 
2. 
SET
 in the center of the right 
touch pad.
Make a time selection in the inverse video minutes 
3. 
or seconds fi eld with the selection keys of the right 
touch pad.