Graupner GmbH & Co. KG MC-20 用户手册
157
Detail program description - Fl. phase timers
The input fi eld in the "Alarm" column is activated with
a tap on the center
a tap on the center
SET
key of the right touch pad.
In this fi eld, use the selection keys on the left or right
touch pad to defi ne a time between 5 and 90 seconds
(in 5-second increments) before zero is reached: at
this point an audible signal will be emitted, which
eliminates the need for you to check the screen
continually during the fl ight.
touch pad to defi ne a time between 5 and 90 seconds
(in 5-second increments) before zero is reached: at
this point an audible signal will be emitted, which
eliminates the need for you to check the screen
continually during the fl ight.
Audible signal sequence
30 s before zero: Triple beep
30 s before zero: Triple beep
Single beep every two seconds
20 s before zero: Double beep
Single beep every two seconds
10 s before zero: Single beep
Single beep every second
5 s before zero: every second a single beep at a
higher frequency
zero: longer beep signal and changeover
of display presentation to inverse
video
video
A simultaneous tap on the
cd or ef keys of the
right touch pad (CLEAR) will reset entry values
entered in the currently active fi eld to "0 s".
entered in the currently active fi eld to "0 s".
Note:
If timer functionality has been changed at any point,
then the new changes to settings are made active
only after the timer(s) have been stopped on the
basic display then making a simultaneous tap on the
cd or ef keys of the right touch pad (CLEAR) to
reset them.
If timer functionality has been changed at any point,
then the new changes to settings are made active
only after the timer(s) have been stopped on the
basic display then making a simultaneous tap on the
cd or ef keys of the right touch pad (CLEAR) to
reset them.
Like the two standard timers positioned above it, this
third, phase-specifi c timer is reset to its starting value
with a simultaneous tap on the
third, phase-specifi c timer is reset to its starting value
with a simultaneous tap on the
cd or ef keys of
the right touch pad (CLEAR). It is stopped in all fl ight
phases at the same time, even if it has not been
stopped separately in the other fl ight phases.
phases at the same time, even if it has not been
stopped separately in the other fl ight phases.
Lap counter/timetable
Timer 1
Timer 2
Timer 3
Lap time/Tim tab
–––
0:00
0:00
0:00
Lap display
0s
0s
0s
–––
–––
–––
–––
Alarm
Timer
On the "Lap time/tim tab" line, assign a switch only
as described in the section "Assigning transmitter
controls, switches and control switches" (page 56).
Preferably, make use of one of the two momentary
switches which are included as standard equipment
in the switch panels. The lap count is incremented
each time by one lap while simultaneously (and
automatically) the lap time elapsed during this lap
is stopped (and recorded). This momentary switch
simultaneously starts the stopwatch for the next lap.
As the timer is triggered, the lap or switch impulse
counter is shown highlighted.
as described in the section "Assigning transmitter
controls, switches and control switches" (page 56).
Preferably, make use of one of the two momentary
switches which are included as standard equipment
in the switch panels. The lap count is incremented
each time by one lap while simultaneously (and
automatically) the lap time elapsed during this lap
is stopped (and recorded). This momentary switch
simultaneously starts the stopwatch for the next lap.
As the timer is triggered, the lap or switch impulse
counter is shown highlighted.
#01
0:00h
Stop watch
Flight tim
K78
0:00.0
4.1V
0:00.0
0
0
0
0
0:00h
M
V
Graubele
H-J Sandbrunner
Normal
Lap
11
2:34.5
RX VOLT:4.9V
"Time1" and "Time2" operate in the same manner; for
more details please read the section on the »Phase
settings« menu option.
Up to 99 lap times can be recorded and accessed,
each with a maximum duration of 99 minutes and
59.9 seconds.
To stop the timer in question, tap the center
more details please read the section on the »Phase
settings« menu option.
Up to 99 lap times can be recorded and accessed,
each with a maximum duration of 99 minutes and
59.9 seconds.
To stop the timer in question, tap the center
ESC
key
of the left touch pad on the basic display after the
fl ight is over. The lap or switch impulse counter is now
shown in "normal" mode:
shown in "normal" mode:
#01
0:00h
Stop watch
Flight tim
K78
0:00.0
4.1V
0:00.0
0
0
0
0
0:00h
M
V
Graubele
H-J Sandbrunner
Normal
Lap
12
1:23.4
RX VOLT:4.9V
A simultaneously tap on the
cd or ef keys of
the right touch pad at the same time (CLEAR) will
reset the counter to "00" and deletes the stored
times. However, the timers must have been stopped
before this.
reset the counter to "00" and deletes the stored
times. However, the timers must have been stopped
before this.
Notes:
If you have selected a normal switch to operate
•
the lap counter, take care to ensure that this
switch is set to "OFF" before touching the center
switch is set to "OFF" before touching the center
ESC
key of the left touch pad.
If you should forget to switch off the lap counter in
•
a phase which is now not currently active, simply
touch the center
touch the center
ESC
key of the left touch pad.
To swap between the basic display and the
"Lap Display" …
"Lap Display" …
01
02
03
04
SEL
01:23.4
02:34.5
03:45.6
05
SEL
04:56.7
05:67.8
07
08
09
10
00:00.0
00:00.0
00:00.0
11
12
00:00.0
00:00.0
00:00.0
06 06:78.9
13
14
15
16
00:00.0
00:00.0
00:00.0
17
18
00:00.0
00:00.0
00:00.0 1/6
… go to the line …