252 Detail program description - Ring limiter
In practice, the setting is made by changing the given 
value until the respective servos in the model just 
reach the point where they no longer move.
A tap on the 
cd or ef keys of the right touch pad at 
the same time (CLEAR) will reset the changed value in 
the active value fi eld back to its "100 %" default value.
In the next line down – labeled at the bottom left of 
the display as " <=> -X" or " <=> -Y", depending 
on the position of the marker frame – the setting 
values, in a range from 0 % and a maximum of 125 %, 
affect the form of limitation between "circular" and 
"rectangular", whereby a setting value here may 
never be greater than the value of the fi eld above it.
Ring Limit  1
0%
100%
CH  4
VSP OUT X
VSP OUT Y
0%
0%
100%
{…–X
0%
CH  3
Ring Limit  1
0%
100%
CH  4
VSP OUT X
VSP OUT Y
0%
0%
100%
{…–X
100%
CH  3
A tap on the 
cd or ef keys of the right touch pad at 
the same time (CLEAR) will reset the changed value 
in the active value fi eld back to its "0 %" default value.
When fi nished with these settings, switch back to 
the fi rst display page for this option then repeat this 
procedure, as applicable, for the lines of ring limiter 
2 or 3.
Final note:
This option can, of course, also be used as necessary 
and applicable for fi xed-wing models.