MTI Co. Ltd. RF25-MWM101 用户手册
BDA Installation and Operating Guide
Version 1.0 11
1.8 Electrical
Specification
1.8.1 Specification
Item
Specification
Remark
Input Frequency
2642 ~ 2672MHz
Output Frequency
2642 ~ 2672MHz
Operating Bandwidth
30MHz
Fixed FH Channel
VSWR
1.5:1
DL/UL
DL
-25 ~ -55dBm/Total
Input
UL
MAX –55dBm/ Total
DL
45~75dB
Gain
Adjustment
Range
UL
45~75dB
Gain Adjustment Step
1dB Step
DL/UL
Gain Adjustment Tolerance
< ±0.7dB
DL/UL
DL
> 20dBm/Toltal
Max. Output
UL
> 20dBm/Toltal
DL
30dB
AGC
UL
30dB
DL
23dBm/Total
Shut Down
UL
23dBm/Total
Impedance (IN/OUT)
50Ω
In-Band
US FCC 04-135 & 27.53
Compliance
Spectral Mask
Out-Band
US FCC 04-135 & 27.53
Compliance
System Delay
< 3.0us
DL/UL
≤5dB
@ Max. Gain
Noise Figure(DL/UL)
≤12dB
@ Min. Gain
Flatness
< 3dB
pk-pk @ BW 30MHz
Frequency Stability
< ±0.02ppm
DL/UL
EVM
<5% (DL:64QAM, UL:16QAM)
Source Comparison
Sync. Signal Detection level (DL)
Min : -75dBm
@ BDA Input
Size(mm)
190 * 250 * 80 (7.6 * 10 *
3.2 inch)
Weight
< 6
kg
Power Consumption
< 40 W
@Instant Max. Power
1.8.2 Functions
Item
Specification
VSWR Alarm
1.5:1
Over Power Alarm
@ Max. Output +2dB
AGC(Auto Gain Control)
30dB
AGD(Auto Gain Difference of DL/UL)
0 ~ 10