Riello Sentinel Dual 3000VA CSDH3K01RU 用户手册
产品代码
CSDH3K01RU
www.riello-ups.co.uk
UP
S
45
As an ECO UPS product, SENTINUAL
DUAL is also fitted with a shut-off button
to reduce energy consumption to zero
during prolonged periods of inactivity.
DUAL is also fitted with a shut-off button
to reduce energy consumption to zero
during prolonged periods of inactivity.
Simplified installation
• SENTINEL DUAL can be installed as a
• SENTINEL DUAL can be installed as a
tower or in 19” rack cabinets, by simply
removing and rotating the mimic panel
removing and rotating the mimic panel
• Low noise (<40dBA) thanks to a high
frequency switching inverter and
load-dependent digitally controlled
ventilation.
load-dependent digitally controlled
ventilation.
• Features guaranteed up to 40°C (the
components are designed for high
temperatures and thus subject to less
stress at normal temperatures)
temperatures and thus subject to less
stress at normal temperatures)
• On SENTINEL DUAL models, the
output sockets can be programmed
to disconnect less critical loads during
blackouts (Power Share function).
to disconnect less critical loads during
blackouts (Power Share function).
Installation versatility
SENTINEL DUAL can be used in a tower
or rack format, by simply turning the
display and adding the supplied feet or
optional runners.
SENTINEL DUAL can be used in a tower
or rack format, by simply turning the
display and adding the supplied feet or
optional runners.
Reduced running costs
The UPS is highly flexible and easy to
configure. Programmable functions can
be set using the software supplied or
manually via the front mimic panel.
SENTINEL DUAL can be configured in the
following operating modes:
• On-line Mode: maximum protection and
The UPS is highly flexible and easy to
configure. Programmable functions can
be set using the software supplied or
manually via the front mimic panel.
SENTINEL DUAL can be configured in the
following operating modes:
• On-line Mode: maximum protection and
output voltage waveform quality
• ECO Mode: to increase output (up to to
98%), using Line Interactive operation.
• Smart Active Mode: the UPS
automatically decides upon the best
operating mode based on the quality of
the network - On-line or Line interactive.
operating mode based on the quality of
the network - On-line or Line interactive.
• Back-up Mode: the UPS can be
selected to function only when the
mains power supply fails.
mains power supply fails.
• Frequency converter (50 or 60 Hz)
• Multi-platform communication for
• Multi-platform communication for
all operating systems and network
environments; supervision and
shutdown PowerShield
environments; supervision and
shutdown PowerShield
3
software for
Windows operating systems 7, 2008,
Vista, 2003, XP, Linux, Mac OS X, Sun
Solaris, VMware ESX and other Unix
operating systems.
Vista, 2003, XP, Linux, Mac OS X, Sun
Solaris, VMware ESX and other Unix
operating systems.
• Standard UPS Tools software supplied
for configuration and customisation
• RS232 serial port and opto-isolated
contacts
• USB Port
• Slot for communication boards such as
• Slot for communication boards such as
Modbus/Jbus, TCP/IP, SNMP and relay
contacts
contacts
Emergency function
This configuration is designed for
emergency systems incljuding lighting,
fire detection/exit systems and alarms.
When the mains power supply fails, the
inverter begins powering the loads with
a progressive start (Soft Start) in order to
prevent overload.
This configuration is designed for
emergency systems incljuding lighting,
fire detection/exit systems and alarms.
When the mains power supply fails, the
inverter begins powering the loads with
a progressive start (Soft Start) in order to
prevent overload.
High quality output voltage
• Even with non-linear loads (loads with a
• Even with non-linear loads (loads with a
crest factor of up to 3:1)
• High short circuit current on Bypass
• High overload capacity 150% on
• High overload capacity 150% on
inverter (even with mains failure).
• Filtered, stabilised and reliable voltage
(On-line double conversion technology
(VFI compliant with EN62040-2 class
C1) with filters for the suppression of
atmospheric disturbances.
(VFI compliant with EN62040-2 class
C1) with filters for the suppression of
atmospheric disturbances.
• Power factor correction: UPS input
power factor, close to 1 and sinewave
current absorption
current absorption
High battery reliability
• Automatic and manual battery test
• Batteries are user replaceable without
• Automatic and manual battery test
• Batteries are user replaceable without
interruption to the load (Hot Swap)
• Unlimited extendible runtime using
matching battery boxes.
Reduced noise
Thanks to the use of high frequency
components and load-based fan speed
control, the noise produced by the UPS is
less than 40dB.
Thanks to the use of high frequency
components and load-based fan speed
control, the noise produced by the UPS is
less than 40dB.
Other features
• Output voltage can be selected using
• Output voltage can be selected using
software (220-230-240V)
• Auto-restart when mains power is
restored (programmable via software)
• Stand-by on Bypass: when the UPS is
switched off, it automatically goes into
bypass and battery charging mode
bypass and battery charging mode
• Minimum load switch-off
• Battery discharge warning
• Start-up delay
• Total microprocessor control
• Automatic bypass without interruption
• Status, measurements and alarms
• Battery discharge warning
• Start-up delay
• Total microprocessor control
• Automatic bypass without interruption
• Status, measurements and alarms
available on standard, backlit display.
• UPS firmware updating via PC
• Input protection through resettable
• Input protection through resettable
thermal switch (versions up to 1500VA)
• Standard Back-feed protection: to
prevent energy from being fed back to
the network
the network
• Manual switching to bypass.
2-YEAR WARRANTY
1. Remove the mimic panel
2. Rotate the mimic panel
and insert it into position
3. Rotate the UPS 90°
4. Attach the rack supports
90°