2.3.2 System Capacity 
Description 
Capacity/Board 
Total 
Time Slots 
 
128 
CO Line Ports 
3/MBU, 3/EMBU, 3/(CHB308, CKB316, 
CSB316), 8/VOIB, 30/E1HB8 
Max. 36 
Max Direct Station (DKT, SLT, 
DSS) Connections 
8/MBU, 8/EMBU, 16/EMBU2,  
8/CHB308, 16/CKB316, 16/CSB316, 
8/VOIB, 8/E1HB8,8/PRHB8 
Max. 48 
External relay contact  
2/MBU 
4  
LAN  
MBU, VOIB, E1HB8, 8/PRHB8 
MODEM Channel 
1/MODU 
Attendant Positions 
Max. 5 + 1/Tenancy Group 
Intercom Links 
Non-Blocking 
Paging 
- All Call 
- Internal 
 
 
1 zone 
5 zones 
Station Speed Dial 
100/station, 24 digits each 
500 
System Speed Dial 
24 digits each 
500 
Last Number Redial 
15 ~ 50 (by admin programming) 
32 digits 
CO Line Group 
Station Group 
10 
10 
Conference 
3~15 Party 
All ports are available
Multi-Conference 
3~15 Party 
Max. 3 groups 
Internal MOH (13 Music Sources) 
1/MBU 
External MOH 
1/MBU 
External Paging port 
1/MBU 
External Relay Contact 
2/MBU, 2/EMBU 
4  
Alarm Input 
1/MBU 
RS-232C Port 
1/MBU 
DTMF/CPT Receiver channels 
16 channels/MBU 
16 channels 
FSK Receiver channels 
16 channels/MBU 
16 channels 
PFT Circuit 
1/MBU, 1/EMBU, 1/CHB308, 1/CSB316 
 
2.3.3 Base station specification (GDC-400B/600B/600BE) 
 
 
Item Specification 
Power feeding 
+30V DC 
Transmission Max Power 
250mW 
Access Method/Duplex 
TDMA/TDD 
Frequency Band 
1,880 ~ 1,900MHz 
Channel Spacing 
1.728MHz 
Modulation GFSK 
Data rate 
1.152Mbps 
Max. Base Station distance from the WTIB 
600m (twisted 2-pair cable)