Reproduction in whole or in part is prohibited. 
 
Once the ePassport is presented to the reader, and the green progress bar indicates data is being 
read, see ICAO Figure #3.  The Passport must continue to be held against the reader until all the 
data has been completely read and the dialog box indicates “Read complete.  Remove passport!”, 
see ICAO Figure #4.  If the dialog box does not indicate “Done” but displays “Please Insert Card 
or Scan Document” the key did not verify (could be a bad scan or invalid key). Rescan the 
document. 
 
Results 
The Document Security Object (SOD), which is a digital signature of the contents of the MRTD 
generated by the issuance agency, is stored within the MRTD. It is very important that the 
Document Security Object (SOD) is authenticated to prove that the Logical Data Structure 
(LDS) is authentic and unaltered.  
Passive Authentication (m) 
– Proves that the contents of SOD and DGs are authentic and not 
changed.  
It cannot, however, protect against perfect duplications of 
the chip or chip substitution. 
Active Authentication (o) 
– Prevents copying SOD, authenticates chip and proves that chip and 
physical passport belong together.  
It can ensure that the chip is 
legitimate and issued by the country claimed 
 
Basic Access Control (o) 
– Prevents skimming, eavesdropping, and misuse.  Th
e e-Passport 
cannot be read by an electronic reader until the machine-readable zone is read first 
Results of AA and PA security features are displayed as follows:  
AA green  :           AA successful  
AA red  
:           AA failed *  
AA orange :           AA not required  
PA green  :           PA successful  
PA red  
:           PA failed *  
PA orange :           PA not required  
* For AA and/or PA failure pressing F4 displays the errors encountered or relevant messages indicating the reason 
of failure.  F4 is used to toggle between displaying errors and displaying geographic details of DG1.  However, F4 
can be used to view errors only when one of these features fails. In all other cases, F4 will navigate you to the 
Scanner tab.  The errors you come across would be due to unsupported signature algorithms and/or hash algorithms. 
 
7.7  Data Capture Enrollment Application (DataCapture,exe) 
The Data Capture enrollment application is used to collect data records that can be stored on a 
memory card and transferred to a PC.  You Must Have a Digital Still Camera installed for this 
application.
 
New Record: Enter the User Data; Name, Doc #, Date, Location, Type. 
Record Composer: