SPRINGCARD SAS PRNHSP01 用户手册

下载
页码 118
PMD2271-BA
page 59 of 118
S
PRING
C
ARD
 PC/SC C
OUPLERS
 - H663 
GROUP
 - Developer's reference manual
4.1.3.
Using the GET DATA instruction
With the GET DATA instruction (documented in § 3.2.1), the host application is able to retrieve
every information needed to identify a PICC:
Serial number (UID or PUPI),
Protocol related values (ATQA and SAKA or ATQB, …).
4.1.4.
Contactless protocol
The standard byte (PIX.SS in PC/SC specification) is constructed as follow:
b7 b6 b5 b4 b3 b2 b1 b0
Value
Description
0
0
0
0
0
0
0
0
h
00
No information given
0
0
0
0
0
0
0
1
h
01
ISO 14443 A, level 1
0
0
0
0
0
0
1
0
h
02
ISO 14443 A, level 2
0
0
0
0
0
0
1
1
h
03
ISO 14443 A, level 3 or 4 (and Mifare)
ISO 18092 @ 106 kbit/s “NFC-A”
0
0
0
0
0
1
0
1
h
05
ISO 14443 B, level 1
0
0
0
0
0
1
1
0
h
06
ISO 14443 B, level 2
0
0
0
0
0
1
1
1
h
07
ISO 14443 B, level 3 or 4
0
0
0
0
1
0
0
1
h
09
ICODE 1, EM4134
0
0
0
0
1
0
1
1
h
0B
ISO 15693
0
0
0
1
0
0
0
1
h
11
JIS:X6319-4
Felica cards
ISO 18092 @ 212 or 424 kbit/s “NFC-F”
Note:  PIX.SS  is defined for both memory and micro-processor based cards, but available in the
ATR for memory cards only. In the other case, use the GET DATA instruction (with parameters
P1,P2=
h
F1,00) to get the underlying protocol used by the smartcard.
SPRINGCARD, the SPRINGCARD logo, PRO ACTIVE and the PRO ACTIVE logo are registered trademarks of PRO ACTIVE SAS.
All other brand names, product names, or trademarks belong to their respective holders.
Information in this document is subject to change without notice. Reproduction without written permission of PRO ACTIVE is forbidden.