SPRINGCARD SAS PRNHSP01 用户手册
PMD2271-BA
page 76 of 118
S
PRING
C
ARD
PC/SC C
OUPLERS
- H663
GROUP
- Developer's reference manual
4.4.5.
Atmel CryptoRF
The PICCs covered by this chapter are:
AT88SC0808CRF (PIX.NN =
h
000A),
AT88SC1616CRF (PIX.NN =
h
000B),
AT88SC3216CRF (PIX.NN =
h
000C),
AT88SC6416CRF (PIX.NN =
h
000D),
AT88SCRF04C (PIX.NN =
h
0034).
The H663 implements the read and write functions in non-authenticated mode. Advanced
functions and authenticated communication has to be implemented by the application within an
ENCAPSULATE instruction.
ENCAPSULATE instruction.
The coupler always activates this PICC with CID=
h
01. Use this CID to build the actual command to
be sent through the ENCAPSULATE instruction.
a.
READ BINARY instruction
In the READ BINARY command APDU,
P1,P2 is the first address to be read,
Le is the length to be read (1 to 32 bytes).
Note: the READ BINARY instruction maps to the “Read User Zone” low-level command. The “Read
System Zone” command is not implemented in the H663, and therefore must be encapsulated.
P1,P2 is the first address to be read,
Le is the length to be read (1 to 32 bytes).
Note: the READ BINARY instruction maps to the “Read User Zone” low-level command. The “Read
System Zone” command is not implemented in the H663, and therefore must be encapsulated.
b.
UPDATE BINARY instruction
In the UPDATE BINARY command APDU,
P1,P2 is the first address to be written,
Lc is the length to be written (1 to 32 bytes).
Note: the UPDATE BINARY instruction maps to the “Write User Zone” low-level command. The
P1,P2 is the first address to be written,
Lc is the length to be written (1 to 32 bytes).
Note: the UPDATE BINARY instruction maps to the “Write User Zone” low-level command. The
“Write System Zone” command is not implemented in the H663, and therefore must be
encapsulated.
encapsulated.
SPRINGCARD, the SPRINGCARD logo, PRO ACTIVE and the PRO ACTIVE logo are registered trademarks of PRO ACTIVE SAS.
All other brand names, product names, or trademarks belong to their respective holders.
Information in this document is subject to change without notice. Reproduction without written permission of PRO ACTIVE is forbidden.