3.
T he number of
S amples per scan
can be varied by choosing one of the
p reset values available in the
S ample per scan
field (Fig. 4-5). H ow ever,
this value can’t be low er than the one indicated in the
Min req.
sample/scan
.
Fig. 4-5 – S amples per scan
4.
T he electroma gnetic w ave p rop agation sp eed can then be set in the
Propagation speed
field (see Fig. 4-6). We r ecom mend y ou accep t the
default value unless y ou have sp ecific information on the typ es of ground
p resent in the area to be investigated.
p resent in the area to be investigated.
Fig. 4-6 – Propagation speed field
4.3
Setting up the Calibration
T his p aragrap h describes the p rocedure used to calibrate the p arameters used in
the real-time p rocessing of r adar data.
the real-time p rocessing of r adar data.
1.
Press the
button show n in Fig. 4-2 to view the w indow
show n in Fig. 4-7, then p erform the automatic ca libration p rocedure by
movin g the antennas across the surface to be scann ed for a d istance of at
least one meter.
movin g the antennas across the surface to be scann ed for a d istance of at
least one meter.
2.
Stop the calibration p hase by p ressing the
button in the
w indow show n in Fig. 4-7. T his p ermits the system to save the filter
p arameters required to view the radar map s in real tim e.
p arameters required to view the radar map s in real tim e.