IDS GeoRadar Srl SRS-FW400 用户手册

下载
页码 76
IDS Ingegneria Dei Sistemi S.p.A. 
Protocol: MN/2009/030 - Rev. 1.2 
Safe Rail System  Data Acquisition Software 
 
 
35 
76 
3.
 
T he  number  of 
S amples  per  scan
  can  be  varied  by  choosing  one  of  the 
p reset  values  available  in  the 
S ample per scan 
field  (Fig.  4-5).  H ow ever,  
this  value  can’t  be  low er  than  the  one  indicated  in  the 
Min  req. 
sample/scan
 
 
Fig. 4-5 – S amples per scan 
 
4.
 
T he  electroma gnetic   w ave  p rop agation  sp eed  can  then  be  set  in  the  
Propagation  speed 
field  (see  Fig.   4-6).  We  r ecom mend  y ou  accep t  the 
default  value  unless  y ou  have  sp ecific  information  on  the  typ es  of  ground  
p resent in the area to be investigated. 
 
 
Fig. 4-6 – Propagation speed field 
 
4.3
 
Setting up the Calibration 
T his  p aragrap h  describes  the  p rocedure  used  to  calibrate  the  p arameters  used  in 
the real-time p rocessing of r adar data. 
1.
 
Press  the 
  button show n  in  Fig.  4-2  to  view   the  w indow 
show n  in  Fig.  4-7,  then  p erform  the  automatic  ca libration  p rocedure  by  
movin g  the  antennas  across  the  surface  to  be  scann ed  for  a  d istance  of  at  
least one meter. 
2.
 
Stop  the calibration p hase by  p ressing the 
 button in the 
w indow   show n  in  Fig.  4-7.  T his  p ermits  the  system  to  save  the  filter 
p arameters required to view  the radar map s in real tim e.